background image

6

 - FORM NO. 56041955 - SOLUS 500 CSA

SET-UP:

1. 

Fill the holding tank with clear water and prespray with the detergent of your choice (we recommend a CRI approved chemical).  Mix well.  

Although this machine is designed to supply instant hot water, the addition of warm water to the holding tank would increase heater ef

fi

 ciency.  

Never use water above 130º F/54º C in the solution tank.

2.  Turn off all the switches.  Plug in cord #1. (This cord runs the pump and vacuum). 

3.  Attach the priming hose to the machine and place the open end into the tank.

4.  Turn on the pump (turn pump pressure dial all the way clockwise) and let it run until the pump is fully primed (approximately 30 seconds 
to 1 minute).  Once the pump is primed, turn off the pump and disconnect the priming hose.  Attach the cleaning hose and tool.

IF YOU WANT HEATED SOLUTION:

5.  Plug in the heater cord (identi

fi

 ed by “H” on the back of the machine). 

NOTE:

  If the green circuit indicator light does not illuminate 

when the heater cord is plugged in, then both cords are on the same circuit.  Try other outlets until the light comes on.  See Bypass 
Switch section (below) if you are unable to get a green light.

6.  Turn the heat knob clockwise to the desired temperature.

7.  Turn on the pump and spray through your tool a few times to 

fi

 ll the lines with solution.  Begin cleaning.

8. Re

fi

 ll and empty the tanks as necessary.

9. When 

fi

 nished with the job, vacuum all unused solution into the recovery tank, and dump the tank.  Clean the tanks and 

fi

 lters.  Clean the 

tool and hoses.  Store the machine in a heated location.

ELECTRIC CIRCUIT LOCATOR:

This unique, patented “smart system,” operated by a solid state circuit, will inform the operator when the two cords are plugged into separate 
lines by illuminating the green, indicator light.  This helps prevent tripping circuit breakers.

BYPASS SWITCH:

The bypass switch (#6) completely bypasses the circuit locator system.  Use this feature when you cannot get the green Locator light (#5) to 
come on and you believe that the two cords are on separate circuits.

 

CAUTION:

  If the bypass switch is on when the two cords are plugged into the same circuit, the breaker in the wall 

panel may trip.

AUTO VACUUM SHUTOFF:

When the recovery tank is full, the 

fl

 oat system will shut off the vacuum motor to prevent the machine from over

fl

 owing.  The 

fl

 oat may not 

work in foam.  Always use a defoamer to prevent over

fl

 ow.  Once the vacuum motor shuts off, the vac switch (#7) must be turned off, the 

recovery tank emptied, and then the vacuum switch turned back on (up position) to get the vacuum motor started again.

 

CAUTION:

  Always make sure the 

fl

 oat is clean and travels freely before turning on the machine.  A 

fl

 oat that is stuck 

will cause the vacuum motor to suck in water, resulting in vac motor damage.

PUMP PRESSURE:

Make sure the cleaning tool is spraying when adjusting the pressure, otherwise the pressure reading will be inaccurate.

Summary of Contents for 56380560

Page 1: ...e 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear gloves or use rags when removing quick disconnects to prevent burns 6 Never use water above 130º F 54º C in the solution tank 6 07 revised 5 11 Form No 56041955 INFORM...

Page 2: ... outdoors or dropped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no long...

Page 3: ...uire any scheduled maintenance however the motors may require replacement brushes after 1000 1500 hours and the pump and bypass valve may require rebuild kits after 1000 1500 hours typically refer to machine part list for numbers Clean the body with an all purpose detergent and protect it with an automobile interior polish Lubricate the wheels castors and quick disconnects with an all purpose sili...

Page 4: ...les are used to move the machine These handles allow you to tilt the machine back onto its 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the machine out of the way of water FAN Removes warm air from the component compartment PSI GAUGE indicates the pump pressure Look at the pressure while you spray LATCH The latch holds together ...

Page 5: ... will be observable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord 2 Identified by the red H on the back of the extractor is on a separate line from cord 1 Cord 2 supplies voltage to the heater allowing it to heat to the temperature range indicated by ...

Page 6: ...nks as necessary 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC CIRCUIT LOCATOR This unique patented smart system operated by a solid state circuit will inform the operator when the two cords are plugged into separate lines by illuminating the green...

Page 7: ...ree strokes Heat exchanger needs to be flushed Wrong tool being used Too much water passing through Longer hose or larger diameter hose than standard NO HEAT Heat is not turned on Either the green light must be on or the bypass switch must be turned on No power in the wall outlet check to see if the breaker has tripped No power to the bypass switch check wiring for opens No power out of bypass swi...

Page 8: ... dans un endroit chauffé NE PAS laisser geler la machine ou le tube rallonge Ne pas l utiliser à l extérieur 3 Ne pas laisser la pompe fonctionner à sec 4 Utiliser uniquement les produits chimiques autorisés AUCUN SOLVANT 5 Porter des gants ou utiliser des chiffons lorsque vous retirez les raccords à démontage rapide pour éviter les brûlures 6 Ne jamais utiliser d eau à une température supérieure ...

Page 9: ...centre de service Ne pas tirer sur le cordon utiliser le cordon comme une poignée fermer un porte sur le cordon ou enrouler le cordon autour de bords ou de coins acérés Ne pas faire passer la machine sur le cordon Éloigner le cordon des surfaces chauffées Pour débrancher tenir la fiche et non le cordon Ne pas manipuler la fiche le cordon ou la machine avec des mains mouillées Les cordons prolongat...

Page 10: ...Products Le moteur d aspiration les moteurs de pompe et les pompes n ont pas besoin d un entretien de routine cependant les brosses des moteurs devraient être remplacer après 1000 ou 1500 heures et la pompe et la soupape de dérivation pourraient avoir besoin de kits de réusinage après 1000 ou 1500 heures consulter la lite des pièces pour les numéros Nettoyer la carrosserie avec un détergent tout u...

Page 11: ...ermettent d incliner la machine vers l arrière sur ses roues de 12 po 30 cm pour une manoeuvre facile ou un déplacement dans les escaliers PLAQUE DE COMMUTATEUR Les commutateurs sont situés à l arrière de la machine à l écart de l eau VENTILATEUR Aspire l air chaud du compartiment des composants MANOMÈTRE indique la pression de la pompe Vérifier la pression quand vous vaporisez LOQUET le loquet re...

Page 12: ...pe pourra être observé sur le manomètre INTERRUPTEUR D ASPIRATION 4 Cet interrupteur s allume quand les moteurs d aspiration fonctionnent Les moteurs d aspiration sont branchés sur le cordon No 1 LOCALISATEUR DE CIRCUIT 5 Quand le témoin lumineux est allumé le cordon No 2 Identifié par un H rouge à l arrière de l extracteur est sur un circuit séparé du cordon No 1 Le cordon No 2 alimente l élément...

Page 13: ...ettoyer 8 Remplir et vider les réservoirs au besoin 9 Quand le travail est fini aspirer toute la solution inutilisée dans le réservoir de récupération et vidanger celui ci Nettoyer les réservoirs et les filtres Nettoyer l outil et les tuyaux flexibles Ranger la machine dans un endroit chauffé LOCALISATEUR DE CIRCUIT ÉLECTRIQUE Ce système intelligent unique breveté activé par un circuit à semi cond...

Page 14: ...r durant 12 à 15 secondes à la fois ou environ trois coups Il faut vidanger l échangeur de chaleur Mauvais outil utilisé Trop d eau passe Tuyau flexible plus long ou d un diamètre plus large que standard PAS DE CHALEUR La chaleur ne fonctionne pas Le témoin lumineux vert doit être allumé ou le commutateur de dérivation doit être ouvert Pas de courant à la prise murale Vérifier si le disjoncteur ne...

Page 15: ...NOTES SOLUS 500 CSA 56380560 120 V ...

Page 16: ...26 28 31 45 36 37 40 38 51 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 54A 44 42 41 43 65 15A 9A 13A 23 Pump inlet hose Pump bypass hose 69 78 79 14A 81 82 80 83 84 ...

Page 17: ...oader 1 Plug Brass Pipe 1 4 Pipe H 1 Elbow 90 Deg 1 4 Mpt X 1 4 1 Elbow 90 Degree 3 8 Brass 2 Bushing 3 8 X 1 4 Pipe Brass 2 Reducer 3 8 Pipe Female To 1 1 Tee Brass 1 4 Pipe 4 Capscrew 1 4 20 X 2 X 1 2 Quick Connect Plug Brass 1 1 Hose Barb 90 Brass 3 8 Ba 1 Hose Barb 1 4 Pipe X 1 2 Hose 1 Nipple Pipe Stainless Steel 1 1 Unloader Valve For 500 Psi Pum 1 Motor Dc Volt100v 300 500 P 1 Bearing Cam A...

Page 18: ......

Page 19: ......

Page 20: ...425 322 0133 800 257 7982 FAX 425 322 0136 11015 47th Ave W Mukilteo WA 98275 VISIT US AT http www usproducts com ...

Reviews: