FORM NO. 56041955 - SOLUS 500 CSA -
7
TROUBLESHOOTING:
IF THIS OCCURS
CHECK THIS
NO SPRAY
Solution tank is empty.
Clogged spray tip.
Pump not running or not primed.
Valve on wand not operating.
PUMP DOES NOT RUN
Check the brushes in the pump motor. Replace if necessary.
No power to pump. Test the Motor Speed Control Circuit Board and potentiometer.
LOW SUCTION
Debris is plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum dome is not seated or is damaged.
NO SUCTION
No power to motor.
Test the Electronic Float.
Test the switch.
Test the vacuum motor.
Test the Vacuum Circuit Board.
LOW HEAT
Spraying too long. Try spraying for 12-15 seconds, or about three strokes.
Heat exchanger needs to be
fl
ushed.
Wrong tool being used. Too much water passing through. Longer hose or larger diameter hose, than
standard.
NO HEAT
Heat is not turned on. Either the green light must be on or the bypass switch must be turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the bypass switch - check wiring for ‘opens.”
No power out of bypass switch, follow troubleshooting steps to isolate the problem.
Call your distributor for additional help.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Solus 500 CSA
Model No.
56380560
Roto-molded Body
Lifetime Warranty
Vacuum
Two 5.7”, 3-stage
VAC Shutoff
Electronic
Pump
Positive displacement, fully adjustable 0-500 psi
Waterlift
100” -- 170 CFM
Heat
Adjustable to 212º F
Heater
2000 Watts
Wand
Stainless steel, double bend, twin tip
Weight
110 lbs.
Dimensions
24W x 28L x 41H (inches)