6
- FORM NO. 56041971 - SOLUS 500 S
1
3
4
6
2
5
HEAT CONTROL (1):
This dial controls the water temperature. Turn it clockwise to
increase water temperature and counterclockwise to decrease
temperature. The heater will operate only if the circuit locator
light (#5) or the bypass switch (#6) is on.
HEAT MODE LIGHT (2):
This light will only illuminate when the heater is heating and will
turn off when it reaches operating temperature. During normal
operation, the “MODE” light will be on most of the time.
PUMP CONTROL (3):
This dial controls motor speed and pump pressure. Adjust
the dial clockwise to increase pressure and counterclockwise
to decrease pressure or turn off pump. The pump runs off of
cord #1. The pump spraying pressure will be observable at the
pressure gauge.
VACUUM SWITCH (4):
This switch will illuminate when the vacuum motors are on.
The vacuum motors run off of cord #1.
CIRCUIT LOCATOR (5):
When this light is on, it indicates that cord #2 (Identi
fi
ed by the
red “H” on the back of the extractor.) is on a separate line from
cord #1. Cord #2 supplies voltage to the heater allowing it to
heat to the temperature range indicated by the Heat Control
dial (#1) on the switch plate.
BYPASS SWITCH (6):
The bypass switch will illuminate when it is activated and will
completely bypass the circuit locator system. Use this system
only when the circuit locator light will not turn on and you know
each cord is on a separate circuit.
CAUTION:
THE CIRCUIT BREAKER IN THE WALL PANEL CAN TRIP
IF BOTH CORDS ARE ON THE SAME CIRCUIT AND THE BYPASS (heat)
SWITCH IS TURNED ON.
NEVER LET YOUR MACHINE OR YOUR WAND FREEZE
SOLUS-500
SWITCH PLATE
Summary of Contents for Souls-500
Page 11: ......