22
SESAMO
DUALCORE
AUTOMATED SYSTEM COMMISSIONING
The commissioning of the Dualcore automated system with P56001 version board and
sensors compliant with EN16005 standard requires the following sequence:
1-
mains power connection (230Vac) and batteries (optional);
2-
Learn Parameters (LP) procedure;
3-
Learn Sensors (LP) procedure;
4-
possible adjustment of parameters;
5-
check of the correct tightening of all screws, of the carriages anti-derailment, of
the box and of all the parts subject to stress and vibrations during operation;
6-
final check of the correct operation of all the safety devices installed with the use
of the specific equipment required by EN16005;
DANGER: each of the activities 1 to 6 listed above is fundamental to the safety of the
system; ensure the person responsible is suitably qualified and do not skip any steps or
checks. Otherwise an important safety function may be disabled and the automatic
movement of the doors may cause serious injury or damage to persons or objects, risking
potentially fatal lesions.
Connect the batteries (if present) and the mains cable (230VAC) to the control unit then
proceed with the self-learning Lp. Refer to fig. 34 of the manual for the passage of the mains
cable from inside to outside of the automated system.
WARNING: if no optional device for night closing control is installed, make sure that
the KEY input is shorted out with the appropriate COM input (terminals 22 and 23);
conversely, it is not possible to start the automated system. For RD100 model, the
connection to the KEY input is in series with the selector switch. Make sure that the key is
set to ON position (led key access).
WARNING: for model RD100, make sure that the emergency button is ON = contact
closed and AUX IN2 led on
PARAMETER ACQUISITION PROCEDURE
(LP)
The parameter acquisition procedure (LP = learn parameters) allows the control unit to
acquire essential data for operation such as the size of the sliding compartment, the weight
of the leaves and the opening direction.
IMPORTANT: before carrying out the LP, make sure that there are no obstacles or excessive
frictions that hinder the sliding of the leaves. Carefully check all the mechanical parts inside
the automated system that interact with the sliding (wheels, carriages, anti-derailment
devices, belt, etc.) and all fixtures in the mobile and fixed parts with particular reference to
the floor guides and the air tightness gaskets or brushes which can be a brake on the sliding
of the leaves. Otherwise, the procedure may not end and could lead to product malfunctions
or excessive wear of some parts.
Summary of Contents for DUALCORE LH100
Page 1: ...LH100 LH140 RD100 ENGLISH AUTOMATED SYSTEMS FOR SLIDING DOORS INSTALLATION MANUAL ...
Page 44: ...44 SESAMO DUALCORE Fig A Fig B ...
Page 45: ...45 SESAMO DUALCORE Fig 1 ...
Page 46: ...46 SESAMO DUALCORE Fig 2 ...
Page 47: ...47 SESAMO DUALCORE Fig 3 ...
Page 48: ...48 SESAMO DUALCORE WARNING Exit way ONLY for RD100 Fig 4 ...
Page 49: ...49 SESAMO DUALCORE Fig 5 ...
Page 50: ...50 SESAMO DUALCORE Fig 5 A ...
Page 51: ...51 SESAMO DUALCORE Fig 6 Fig 7 ...
Page 52: ...52 SESAMO DUALCORE Fig 8 Fig 9 ...
Page 53: ...53 SESAMO DUALCORE Fig 9a Fig 10 ...
Page 54: ...54 SESAMO DUALCORE Fig 11 Fig 12 ...
Page 55: ...55 SESAMO DUALCORE Fig 13 Fig 14 Fig 15 ...
Page 56: ...56 SESAMO DUALCORE Fig 16 Fig 16a ...
Page 57: ...57 SESAMO DUALCORE Fig 17 Fig 17a ...
Page 58: ...58 SESAMO DUALCORE Fig 18 Fig 19 Fig 20 ...
Page 59: ...59 SESAMO DUALCORE Fig 21 Fuses 6 3A T J ...
Page 60: ...60 SESAMO DUALCORE Fig 22 ...
Page 61: ...61 SESAMO DUALCORE Fig 23 1 Fig 23 2 ...
Page 62: ...62 SESAMO DUALCORE Fig 24 PARAMETER 30 1 ...
Page 63: ...63 SESAMO DUALCORE Fig 25 PARAMETER 30 1 Exit way ...
Page 64: ...64 SESAMO DUALCORE Fig 25 A ...
Page 65: ...65 SESAMO DUALCORE Fig 26 ...
Page 66: ...66 SESAMO DUALCORE Fig 27 PARAMETER 31 1 ...
Page 67: ...67 SESAMO DUALCORE Fig 28 PARAMETER 31 0 ...
Page 68: ...68 SESAMO DUALCORE Fig 29 ...
Page 69: ...69 SESAMO DUALCORE Fig 30 Fig 31 ...
Page 71: ...71 SESAMO DUALCORE Fig 33 ...
Page 72: ...72 SESAMO DUALCORE Fig 34 ...