5
SESAMO
DUALCORE
TECHNICAL SPECIFICATIONS
SIZES
See Fig.1
POWER SUPPLY
230V ±10% AC 50/60Hz
RATED POWER
LH100 = 150 W
LH140/RD100 = 180 W
EXTERNAL DEVICES POWER
15Vdc - 12W MAX
BATTERY BACKUP POWER
LH100/LH140 = 24V 1,3Ah
RD100 = 24V 2Ah
OPENING SPEED
1 Leaf = 70cm/s
2 Leafs = 140 cm/s
PASSAGEWAY
1 Leaf LH100/LH140 = 700 ÷ 3000 mm
1 Leaf RD100 = 800÷ 3000 mm
2 Leafs LH100/LH140 = 900 ÷ 3000 mm
2 Leafs RD100 = 900÷ 3000 mm
PAYLOAD
LH100 1 Leaf = 140 kg
LH100 2 Leafs 100+100 kg
LH140 1 Leaf = 160 kg
LH140 2 Leafs = 140+140 kg
RD100 1 Leaf = 150 kg
RD100 2 Leafs 130+130 kg
OPERATING TEMPERATURE
-10°C +55°C
ANTI
-
CRUSHING
Automatic limitation of the force in the presence
of obstacles
WEIGHT
around 11 kg/m
SERVICE
Continuous
PROTECTION
IP20
INTENDED USE
LH100/LH140/RD100 automated systems must be used exclusively for the movement of
sliding pedestrian doors. In particular, the RD100 version is designed for doors installed on
exit ways in compliance with the requirements of EN 16005 standard - paragraph 4.7.2.
RD100 adopts some components in redundant form and is equipped with two gearmotors
and two electronic control units. The two control units (Master (G)
–
Slave (P) fig. 5/A) allow
continuous and crossed monitoring of the operation and a special algorithm assigns control
to one control unit in case the other is faulty. The double motor with alternating drive at
each maneuver ensures continuous operation self-test and guarantees safe opening and
positioning in case of failure of one of the two motors. RD100 control units are equipped
with a special input to operate in conjunction with sensors in compliance with EN 13849-1
performance level "d" Cat.2 specially designed to guarantee the safe opening of the doors
installed on exit ways.
WARNINGS FOR THE TECHNICIAN
(
GENERAL SAFETY OBLIGATIONS
)
1)
It is important to install the automated system according to instructions in order to
ensure the safety of people. Improper installation or incorrect use of the product can cause
serious injury to people.
Summary of Contents for DUALCORE LH100
Page 1: ...LH100 LH140 RD100 ENGLISH AUTOMATED SYSTEMS FOR SLIDING DOORS INSTALLATION MANUAL ...
Page 44: ...44 SESAMO DUALCORE Fig A Fig B ...
Page 45: ...45 SESAMO DUALCORE Fig 1 ...
Page 46: ...46 SESAMO DUALCORE Fig 2 ...
Page 47: ...47 SESAMO DUALCORE Fig 3 ...
Page 48: ...48 SESAMO DUALCORE WARNING Exit way ONLY for RD100 Fig 4 ...
Page 49: ...49 SESAMO DUALCORE Fig 5 ...
Page 50: ...50 SESAMO DUALCORE Fig 5 A ...
Page 51: ...51 SESAMO DUALCORE Fig 6 Fig 7 ...
Page 52: ...52 SESAMO DUALCORE Fig 8 Fig 9 ...
Page 53: ...53 SESAMO DUALCORE Fig 9a Fig 10 ...
Page 54: ...54 SESAMO DUALCORE Fig 11 Fig 12 ...
Page 55: ...55 SESAMO DUALCORE Fig 13 Fig 14 Fig 15 ...
Page 56: ...56 SESAMO DUALCORE Fig 16 Fig 16a ...
Page 57: ...57 SESAMO DUALCORE Fig 17 Fig 17a ...
Page 58: ...58 SESAMO DUALCORE Fig 18 Fig 19 Fig 20 ...
Page 59: ...59 SESAMO DUALCORE Fig 21 Fuses 6 3A T J ...
Page 60: ...60 SESAMO DUALCORE Fig 22 ...
Page 61: ...61 SESAMO DUALCORE Fig 23 1 Fig 23 2 ...
Page 62: ...62 SESAMO DUALCORE Fig 24 PARAMETER 30 1 ...
Page 63: ...63 SESAMO DUALCORE Fig 25 PARAMETER 30 1 Exit way ...
Page 64: ...64 SESAMO DUALCORE Fig 25 A ...
Page 65: ...65 SESAMO DUALCORE Fig 26 ...
Page 66: ...66 SESAMO DUALCORE Fig 27 PARAMETER 31 1 ...
Page 67: ...67 SESAMO DUALCORE Fig 28 PARAMETER 31 0 ...
Page 68: ...68 SESAMO DUALCORE Fig 29 ...
Page 69: ...69 SESAMO DUALCORE Fig 30 Fig 31 ...
Page 71: ...71 SESAMO DUALCORE Fig 33 ...
Page 72: ...72 SESAMO DUALCORE Fig 34 ...