Programming option definitions:
Lock operates on a 3V lithium coin cell CR2450 battery located on back side of
device. Remove screw located on cover of battery and replace it with new battery.
Battery life is up to 10 years. The red LED light blinks 5 times after each operation
when battery is low and it is possible to open and close lock for 100-150 times
after you get the initial low battery warning.
Changing the battery:
0
Restoring factory settings: All factory default settings are restored (see program menu). User
password becomes <1-0-1-0> and master password becomes <1-0-1-0-1-0>.
1
Usage options: Factory default is Personal mode allows one 4-digit code to be entered that
would remain the same code for one user. Locker mode is for multiple users whereby each user
walks up to an open miniK10 and enters in their own unique code to close the lock and then to
open it again. When open, next user enters in a new code, etc.
2
Audible volume control: All audio warnings can be turned off if mute operation is selected
(except warning beeps).
3
Penalty operation: Prevents tampering of lock by unauthorized people. Lock is blocked for 5
min if wrong password is entered three times consecutively. Factory default is that this feature
is not active.
4
User code reset: Sets user factory default to <1-0-1-0>.
5
Service password: Lock can be opened with service password if user password is forgotten.
Factory service default password is <1-0-1-0-1>. No programming features can be accessed
with service password. Factory default is that this feature is not active.
6
Closing modes: Factory default - miniK10 does not require a password to lock. The other
option is it can require a password to lock.
7
Lock open warning: After lock is open for one minute, lock gives an audible warning to user
with 8 beeps every 5 sec to notify user that the lock has been left open.
8
Resetting user password: If the lock is opened with service password (and service password
is active), user password can be reset. (see program #5 on service passwords). Factory default
is that the service password access does not allow the user password to be reset (only opens
up the lock).
9
Blocking the lock: If lock opened with service password, it can be blocked from further user
password access.This would. insure service password is only used to access locks for emergen-
cy lockouts. Master password access would then be required to set up user password again
(0-1 Factory default reset). Factory default is that this feature is passive.
9
Summary of Contents for Minik 10
Page 1: ...CABINETS LOCKERS BOXES Operating manual The easy lock in every aspect ...
Page 14: ...CABINETS LOCKERS BOXES Installation The easy lock in every aspect ...
Page 17: ...Surface Mounting Semi Flush Mounting 17 ...
Page 20: ...Joint erect lock assembly measurements 22 mm axle cam 38 mm axle cam 20 ...