CARATTERISTICHE

• Tensione di funzionamento:

8-12 V.

• Indicazione batteria scarica:

8 V.

• Formato batteria:

23 A

• Assorbimento tipico:

2 mA

• Assorbimento:

1,6-2,2 mA max.

• Tempo di funzionamento: 300

ore tipiche

• Massimo offset:

(+/-) 5 mV

• Massima lunghezza dei conduttori da

ADM a Voltmetro (suggerita):

20 m.

• Diametro jack

3,5 mm

• Misure

36x60(76)x18 mm

LEGENDA

1 Led verde: adattatore in funzione
2 Led rosso: batteria scarica
3 Pulsante rosso: attivazione/spegnimento
4 Spinotto negativo
5 Spinotto positivo
6 Commutatore a tre posizioni: Detector -

Fire - Smoke

Adattatore ADM ~ ADM Adapter ~ ADM-Adapter

1

2

3

4

5

6

6

0

m

m

36 mm

18 mm

CHARACTERISTICS

• Working tension:

8-12 V.

• Flat battery indicator:

= 8 V.

• Battery format:

23 A

• Typical input:

2 mA

• Absorption:

1,6-2,2 mA max.

• Working time:

typically 300 hours

• Maximum offset:

(+/-) 5 mV

• Maximum length of leads from

ADM to Voltmeter (recommended): 20 m

• Jack diameter

3,5 mm

• Size

36x60(76)x18 mm

LEGEND

1 Green Led: working adapter
2 red Led: flat battery
3 Red button: switching on/off
4 Negative gudgeon pin
5 Positive gudgeon pin
6 Three-position switch: Detector - Fire –

Smoke

Merkmale

• Betriebsspannung

8-12V

• Anzeige Batterie schwach

= 8V

• Batterie

23A 12V

• Stromaufnahme

1,6 – 2,2mA

• Betriebszeit bei norm. Bed. bis

300Std

• Max. Offset

+/- 5mV

• Maximale Länge der Leitungen vom

ADM Adapter zum Voltmeter

20m

• Klinkenstecker

3,5 mm

• Maße

36X60X18mm

ADM ANSICHT

1 LED grün: Betriebsanzeige
2 LED rot: Batterie schwach
3 Schalter Ein/Aus
4 Banenstecker Ø 4 mm (-)
5 Banenstecker Ø 4 mm (+)
6 3-Stufen-Schalter: Detector - Fire -

Smoke

SETRONIC Verona

ADM Adapter

Rev. 00

Summary of Contents for ADM

Page 1: ...SMOKE and FIRE BEAM DETECTORS ADM ADAPTER ...

Page 2: ...8 V Battery format 23 A Typical input 2 mA Absorption 1 6 2 2 mA max Working time typically 300 hours Maximum offset 5 mV Maximum length of leads from ADM to Voltmeter recommended 20 m Jack diameter 3 5 mm Size 36x60 76 x18 mm LEGEND 1 Green Led working adapter 2 red Led flat battery 3 Red button switching on off 4 Negative gudgeon pin 5 Positive gudgeon pin 6 Three position switch Detector Fire S...

Page 3: ...ioning systems any steam or heat producing machi nes etc If the installation position for the detector is right the DETECTOR readings will stay around an average of between a negative value 30 mV and a positive value 70 mV WARNING As regards this average you must also remember the peak values ARDEA RANGE mod ARDEA S 2 ARDEA SF ARDEA SF Dust 1 Read the DETECTOR value by setting switch 6 to the DETE...

Page 4: ...eizungen EMV Einflüsse usw Die Spitzen Werte bei den größtmöglichen Aktivitäten im Gebäude sollten gemessen werden Wenn die Installation Montageposition korrekt ist werden Durchschnittswerte etwa zwischen 30 und 70 mV angezeigt sehr kurzfristige Anstiege bis ca 200 sind dabei normal HINWEIS Sowohl die Durchschnitts als auch die Spitzenwerte müssen beachtet werden ARDEA MODELLE mod ARDEA S 2 ARDEA ...

Page 5: ... ambiente es accensione e spegnimento di impianti di illuminazione impianti di riscaldamento condizionamento eventuali macchinari generanti vapori calore etc etc Se la scelta della posizione d installazione del rilevatore è stata opportuna i valori di DETECTOR permarranno at torno ad una media compresa tra un valore negativo 30 mV ed un valore positivo 70 mV ATTENZIONE Rispetto questa media dovran...

Page 6: ...e or in part including in digital form the images and or data without formal prior authorisation from our Company Legal action will be taken in case of infringement Setronic ist der alleinige Inhaber der Urheberrechte aller Daten und Abbildungen in dieser Anleitung Ohne formale Genehmigung ist es ausdrücklich verboten Kopien dieser Daten und Abbildungen als Ganzes oder in Auszügen anzufertigen Jed...

Reviews: