background image

cleaner at least once a year.

Remark:

Do not use abrasive tools or materials containing alcohol or harsh cleaning

solutions. Do not use any electrical appliances, such as steam cleaners etc., for de-frosting or
cleaning.

Trouble-shooting

Certain typical sounds can be heard when the appliance is switched on. These sounds are:

- Caused by the electrical motor within the compressor

assembly;  during compressor start-up the sound level will be
slightly higher for a limited period of time.

- Caused by the cooling agent flowing through the circuit. 

The following table lists the possible malfunctions, their probable causes and solutions. In
the event of operational problems, check first whether a solution can be found using this
table. If the problem persists, disconnect the appliance from the mains power and contact
our Customer Service Department.

14

Problem 

The appliance is connected to the mains,
but does not operate. 

Abnormal noise can be heard during
freezer operation. 

When opening the door, the rubber seal
pops out. 

Possible cause and solution  

The wall socket has no power, or there are
contact problems. Check the wall socket
and the plug.  

Either the unit has been improperly set up
(e.g. on an uneven floor) or there is contact
between the rear-mounted cooling circuit
and the power cord, the wall or other
object or surface. Verify that all
installation instructions in this manual
have been correctly complied with.  

The seal must be re-fitted properly, by
pressing in the inner part of the seal. If the
seal shows signs of a greasy residue, the
seal and the door must be properly cleaned
with water and a mild detergent, and then
thoroughly dried before the seal is
replaced in the door.   

Transporting the appliance

The unit must be transported only in its vertical position.
Do not tilt it any more than 30°. During transport, ensure that the unit is properly secured
and protected against shock, vibration and shifting.

Summary of Contents for KS 9804

Page 1: ...high level of environmental compatibility which is nevertheless flammable Ensure therefore that none of the components of the refrigerant circuit become damaged during transportation and installation of the appliance If damage to the cooling circuit does occur do not switch on or connect the appliance to the mains power In the case that there is an open fire or any other sources of ignition in the...

Page 2: ...ision and never let children play with the appliance In order to comply with safety regulations and to avoid hazards any repairs or modifications to this unit must be carried out by our authorised service personnel including the replacement of the power cord We reserve the right to introduce technical modifications If the unit is not used for an extended period of time we recommend keeping the doo...

Page 3: ...et to the same height Ventilation The heated air around the rear of the freezer must be able to circulate freely Therefore ensure that the air circulation behind the unit is not obstructed Reversible door The design provides for the door to be reversed i e for right hinged default installation to become left hinged 1 Remove the hinge cover 1 2 Use a suitable pointed tool to remove the cover 5 3 Us...

Page 4: ...vents frozen food from becoming partially thawed Prior to freezing fresh food e g meat fish minced meat should be divided into smaller portions suitable for use after thawing When storing pre frozen food strict attention should be paid to the manufacturer s information provided on the packaging If no such information is to be found however a storage period of 3 months from the date of purchase mus...

Page 5: ...kness of 3 to 5 mm the unit must be de frosted The build up of ice increases the power consumption of the appliance When de frosting the unit Ensure that the plug has been removed from the wall socket Remove all food from the freezer place it into a plastic container add pre frozen freezer packs and cover the container to keep the inside temperature down Leave the freezer door open Warning Do not ...

Page 6: ...e appliance is connected to the mains but does not operate Abnormal noise can be heard during freezer operation When opening the door the rubber seal pops out Possible cause and solution The wall socket has no power or there are contact problems Check the wall socket and the plug Either the unit has been improperly set up e g on an uneven floor or there is contact between the rear mounted cooling ...

Page 7: ...chase Under this guarantee the manufacturer undertakes to repair or replace any parts found to be defective providing the product is returned to one of our authorised service centres This guarantee is only valid if the appliance has been used in accordance with the instructions and provided that it has not been modified repaired or interfered with by any unauthorised person or damaged through misu...

Page 8: ... actual consumption depends on the pattern of use and the location of the appliance Max usable capacity litres 45 Climate classification N Ambient temperature range C 16 32 Safe storage time in case of malfunction hours 14 Freezing capacity kg 24h 2 Freezing temperature C 18 Dimensions in mm 490 x 500 x 495 Weight kg 22 Electrical specifications See rating plate Insulation foam C5H10 16 ...

Reviews: