6
Electrical installation
Connection with plug connectors
Addendum to the Operating Instructions – AH0E and AK0J Encoders
16
6.2.5
Motor connection SJB (M40) for motors with AK0J encoder without/with BK.. and BZ..D
brake
The wiring diagram of the plug connector depicts the contact end of the connections.
Function
Motor connection for motors with AK0J encoder
Connection type
M40, male, external thread, TE Connectivity – Intercontec products, 940 series,
SpeedTec equipment
Connection diagram
N
2
D +
D –
W
V
PE
U
+
–
1
Assignment without brake
Contact
Signal
Description
+
Reserved
Do not connect
-
Reserved
Do not connect
1
Reserved
Do not connect
2
Reserved
Do not connect
PE
PE
PE connection
U
U
Motor connection phase U
V
V
Motor connection phase V
W
W
Motor connection phase W
N
Reserved
Do not connect
D +
D +
Data + (serial data transfer)
D -
D -
Data - (serial data transfer)
Assignment with BK.. and BZ..(D) brake
Contact
Signal
Description
+
Brake +
BK.. brake + / BZ..D +
-
Brake -
BK.. brake - / BZ..D -
1
Reserved
Do not connect
2
Reserved
Do not connect
PE
PE
PE connection
U
U
Motor connection phase U
29149851/EN – 04/2020