5
Electrical installation
Connecting the plug connector - Two-cable technology
Operating Instructions – CM3C63 – 100
33
Wiring diagram SM1./SB1. with/without BZ../BZ..D brake
Connect the shield to the metal housing of the connector. The color code corresponds
to the cables from SEW‑EURODRIVE.
D
C
B
A
3
1
4
BU
GNYE
RD
BK
U1
V1
W1
D
C
B
A
3
1
4
BK
GNYE
BK
BK
U
V
W
BK (3)
BK (2)
13
14
15
BK (1)
RD
BU
WH
[B]
[1]
[1] [A]
[2]
9007228536929291
[1]
BZ../BZ..D brake (optional)
[2]
Connection to rectifier from SEW‑EURODRIVE according to operating instructions. For BZ..D, there is
no port 14 (contact B).
26870460/EN – 05/2021