5
Electrical installation
Connecting the plug connector - Two-cable technology
Operating Instructions – CM3C63 – 100
34
5.6.3
Connection SMB/SBB power plug connector with/without brake
The following table shows information about this connection:
The wiring diagram of the plug connector depicts the contact end of the connections.
Function
Power connection
Connection type
M40, TE Connectivity - Intercontec Products, series 940, SEW insert, speedtec
equipment, coding ring: without, male
Connection diagram
+
1
-
2
PE
W
V
U
Assignment for motor without brake
Contact
Signal
Description
+
Reserved
Do not connect
-
Reserved
Do not connect
1
Reserved
Do not connect
2
Reserved
Do not connect
PE
PE
PE connection
U
U
Motor connection phase U
V
W
Motor connection phase W
W
V
Motor connection phase V
Assignment for brakemotors with BK.. brake
Contact
Signal
Description
+
Brake +
BK brake +
-
Brake -
BK brake -
1
Reserved
Do not connect
2
Reserved
Do not connect
PE
PE
PE connection
U
U
Motor connection phase U
V
W
Motor connection phase W
W
V
Motor connection phase V
26870460/EN – 05/2021