26
Operating Instructions – Synchronous Compact Servomotors CMDV55 – CMDV162
5
Connecting the motor and the encoder system via plug connector SM. / SB.
Electrical Installation
Signal plug connectors RH1M resolvers
Wiring diagram
Signal plug connectors for EK1H, AK1H, AK0H, EK0H encoders
Wiring diagram
5.5.6
Wiring diagrams of the brake control – BP brake
If the servomotors are operated on the MOVIAXIS
®
servo inverter, overvoltage protec-
tion is provided.
In every application, the BP holding brake can be controlled via the BMV brake rectifier
or a customer relay with varistor overvoltage protection.
If the system complies with the specifications for direct brake control, then a BP brake
can also be controlled directly via the brake output of a MOVIAXIS
®
servo inverter.
However, the brakes of the motors cannot be directly connected to MOVIAXIS
®
. For
detailed information, refer to the "MOVIAXIS
®
Multi-Axis Servo Inverter" system manual.
If the servomotors are operated on MOVIDRIVE
®
or inverters of other manufacturers,
overvoltage protection must be implemented by the customers themselves using varis-
tors, for example.
Observe the notes in the relevant operating instructions for the inverters concerning the
switching sequence of motor enable and brake control during standard operation.
1
9
8
2
10
12
7
3
4
5
6
11
GY
RD
BU
BNVT
GN
YE
2
3
4
6
9
PK
WHBK
1
10
S2 (Sine +)
S4 (Sine -)
1
9
8
2
10
12
7
3
4
5
6
11
BKWH
BU (BK)
RD
RD (BK)
BU
YE
KTY+ (TF)
R1 (Ref)
RDWH
BK
R2 (Reference -)
KTY- (TF)
S1 ()
S3 (Cosine -)
5
A
B
P
1
9
8
2
10
12
7
3
4
5
6
11
GN
RD
BU
BN
RDBU; GY
YE
12
3
4
6
9
VT
WH
7
10
GYPK; PK
11
8
BK
BU
1
9
8
2
10
12
7
3
4
5
6
11
RD
GN
YE
S2 (Sine +)
S4 (Sine -)
S1 ()
S3 (Cosine -)
BK
VT
GY
D +
D -
Us
PK
GND
BU (BK)
RD (BK)
KTY+ (TF)
KTY- (TF)
5
A
B
P