Using the DBG60 Keypad
4
Step 7
Select
PARAMETER SET
1
.
Step 8
Select
SINGLE MOTOR
.
Step 9
Select
STANDARD V
/
F
mode.
Step 10
Select
NO
for
DC BRAKING
.
Step 11
Select the correct motor class. You may need to ask for help if you are not familiar with
SEW-EURODRIVE motors.
Step 12
Select the correct motor model (obtained from the nameplate).
Step 13
Enter the correct motor voltage (obtained from the nameplate).
Step 14
Enter the correct motor frequency (obtained from the nameplate).
Step 15
Enter the MOVIDRIVE
®
B’s supply voltage (ask the instructor if you’re not sure).
Step 16
Select
NO RESPONSE
for motor thermal protection.
Step 17
Select
YES
for
CALCULATION
.
Step 18
Select
YES
for
SAVE
.
Step 19
Press the
EXIT
button.
Now you can test the MOVIDRIVE
®
B by running it in manual mode.
Step 1
Press the
MOVE UP
/
MOVE DOWN
buttons until
MANUAL OPERATION
appears.
Press the
CONFIRM
button.
Step 2
Flip
DI 00
to the ON (up) position.