120
Manual – IPOSplus®
11
Introduction
IPOSplus
®
for MQx – Characteristics
11
IPOS
plus
®
for MQx – Characteristics
11.1 Introduction
In the same way as for MFx modules, modules of the MQx series allow a cost-effective
fieldbus interface to MOVIMOT
®
drives. In addition, the MQx modules are equipped with
control functions that help you determine how the drive responds to external input via
fieldbus and integrated I/Os.
This allows, for example, sensor signals to be processed directly at the fieldbus interface
or allows users to define their own communication profile via the fieldbus interface. The
NV26 proximity sensor provides you with a simple positioning system that can be inte-
grated in systems in conjunction with an MQx control program as standard components.
In principle, the same IPOS
plus®
program as used in MOVIDRIVE
®
A runs in the MQx
interface. However, full functionality cannot be realized in some cases. The following
section describes these differences.
• The parameter group P900 IPOS
plus®
parameters is not implemented for the MQx
interface.
• As with MOVIDRIVE
®
A, the MQx fieldbus interface provides two tasks with the same
command processing times for IPOS
plus®
commands.
• When using the IPOS
plus®
variable H511 (ActPos_Mot), the NV26 encoder does not
count 4096 inc./revolution but 24 inc./revolution.
• Not all IPOS
plus®
commands can be used.
P
i
f
kVA
Hz
n
P
i
f
kVA
Hz
n