Manual – IPOSplus®
87
6
Cam controllers
Position Detection and Positioning
Example
A travel drive has a travel range of ten motor revolutions.
An output is to be set when the drive is in the first and in the last motor revolution or in
a range of +/- 10° around the center of the travel range. A second output is to be set
when the drive is in the second revolution.
Required parame-
ter settings
P620 = IPOS
plus®
output
P621 = IPOS
plus®
output
477561867
0
t
3600° / 40960 Inc
t
t
360° / 4096 Inc
720° / 8192 Inc
0
1
1
H481.1
H481.2
3240° / 36864 Inc
P
i
f
kVA
Hz
n
P
i
f
kVA
Hz
n