138
Manual – IPOSplus®
12
P95x absolute encoder (SSI)
P9xx IPOS Parameters
12.6 P95x absolute encoder (SSI)
The DIP parameters are described in detail in the "MOVIDRIVE
®
MDX61B Absolute En-
coder Card DIP11B/DEH21B" manual. The DIP11B option cannot be used with
MOVIDRIVE
®
MDX61B size 0.
12.6.1 P950 Encoder type
The absolute encoder connected to the DEH21B/DIP11B option (X62) is selected. At
present, encoders can be selected from the following list:
• VISOLUX EDM
• T&R CE65, CE58, CE100 MSSI
• T&R LE100, LE200
• T&R LA66K
• AV1Y/ROQ424
• STEGMANN AG100 MSSI
• SICK DME -3000-111
• STAHL WCS2-LS311
• STEGMANN AG626
• IVO GM401, GXMMW A202PA2
• STAHL WCS3
• LEUZE OMS1, OMS2
• T&R ZE 65M
• LEUZE BPS37
• SICK DME 5000-111
• POMUX KH53
• KÜBLER 9081
• LEUZE AMS200
• MTS TEMPOSONICS RP
• P+F AVM58X-1212
• Hübner HMG161 S24 H2048
• Balluf BTL5-S112B-M1500
• T&R LA41K
• Elgo LIMAX2
12.6.2 P951 Counting direction
Setting range: NORMAL/INVERTED
Defines the counting direction of the absolute encoder. The setting must be made so the
counting direction of the motor encoder (X15) and the absolute encoder (X62) match.