Inspection and maintenance
Inspection and maintenance intervals
Operating Instructions – MOVIGEAR
®
classic
70
Time interval
What to do?
Who is permitted to
perform the work?
When the cover / elec-
tronics cover is removed
after an operating
period of ≥ 6 months.
When the cover / electronics cover
is opened after an operating
period of ≥ 6 months, the gasket
between the connection box and
the cover / electronics cover must
always be replaced.
The 6-month period can be
shortened by harsh ambient/oper-
ating conditions, e.g. cleaning with
aggressive chemicals or frequent
temperature fluctuations.
Qualified personnel at
customer site
Each time the cover /
electronics cover is re-
moved
Visual inspection of the gasket
between connection box and
cover / electronics cover: The gas-
ket must be replaced in the event
of damage.
Qualified personnel at
customer site
Varying (depending on
external factors)
Touch up or renew the surfaces/
anti‑corrosion coating.
Qualified personnel at
customer site
To prevent permanent water accu-
mulation in the B-side safety
cover, you must clean it at regular
intervals.
Qualified personnel at
customer site
1) Wear times are influenced by many factors. The system manufacturer must calculate the required in-
spection/maintenance intervals individually in accordance with the project planning documents.