8
Inspection and maintenance
Inspection and maintenance work
Operating Instructions – MOVIGEAR
®
classic
72
8.3
Inspection and maintenance work
8.3.1
Preliminary work regarding inspection and maintenance
Observe the following notes before you start with inspection/maintenance work on the
MOVIGEAR
®
classic:
WARNING
Risk of injury if the drive starts up unintentionally.
Electric shock caused by dangerous voltages in the connection box.
•
Before removing the cover, de-energize the drive units via a suitable external dis-
connection device.
•
Secure the drive unit against unintended re-connection of the voltage supply.
•
Secure the output shaft against rotation.
WARNING
Risk of burns due to hot surfaces and hot gear unit oil.
Serious injuries.
•
Let the devices cool down before touching them.
•
Remove the screw plugs and the breather valve carefully.
•
The gear unit must still be warm, otherwise the high viscosity of excessively cold
oil will make it more difficult to drain the oil correctly.
NOTICE
Damage to the drive unit.
Potential damage to property.
•
Make sure that only the SEW‑EURODRIVE Service or qualified personnel
trained by SEW‑EURODRIVE opens the gear unit cover.
NOTICE
Filling in the wrong oil may result in significantly different lubricant characteristics.
Potential damage to property.
•
Do not mix different synthetic lubricants and do not mix synthetic and mineral lub-
ricants.
•
Synthetic oil is used as the standard lubricant.