9
Technical data and dimension sheets
Derating for increased ambient temperature
Operating Instructions – MOVIGEAR
®
classic
83
9.4
Derating for increased ambient temperature
The following derating applies for operating the drive unit in the ambient temperature
range from +40 °C to +60 °C:
The thermal speed/limit torque characteristic curve is re-scaled towards the origin
(minimized). The thermal operating point based on rms torque and thermally effective
speed of the application must be below the re-scaled characteristic curve.
M
0
(T
U
)
n
N
M
0
n
N
(T
U
)
23044129163
M
T
M
C
T
C
n
T
K
n
C
T
C
U
U
N
U
e
N
U
0
0
145
105
145
105
( )
=
×
° −
°
( )
=
×
×
° −
°
T
U
Ambient temperature [°C]
M
0
Standstill torque under nominal conditions
M
0
(T
U
)
Standstill torque at increased temperature 40 °C < T
U
< 60 °C
n
N
Rated speed
n
N
(T
U
)
Rated speed at increased temperature 40 °C < T
U
< 60 °C
K
e
Transmitter factor = 1
25805134/EN – 07/2018