Activating terminals X4 for temperature sensor
Adhere to the following sequence when activating the terminals X4 for temperature
sensor:
Before removing the conductor, first press the actuation button on top.
Terminals X4 for temperature sensor
(the following figure shows a schematic illustration)
Connect conductor,
without pushing the activation button.
Connect conductor,
after pressing the activation button.
22904860811
1.
2.
22904932619
The following conductors can be installed
directly (without tool) up to two cross-sec-
tion sizes below the nominal cross sec-
tion:
•
Single-wire conductors
•
Flexible conductors with end sleeves
When connecting the following conduct-
ors, you must press the actuation button
on top to open the clamping spring:
•
Untreated, flexible conductors
•
Conductors with small cross sections
that cannot be plugged in directly.
Remove the conductor.
First press the activation button.
1.
2.
22904940427