6
Startup
Startup notes
Operating Instructions – MOVIGEAR
®
classic
63
6
Startup
6.1
Startup notes
INFORMATION
•
It is essential to comply with the safety notes during startup.
•
Correct project planning for the drive is a prerequisite for successful startup. For
project planning notes, refer to the catalog.
•
The motor speed must not exceed 2000 min
-1
. Set the maximum speed on the fre-
quency inverter. For information on the procedure, refer to the documentation of
the frequency inverter.
6.2
Prerequisites for startup
6.2.1
Before startup
Make sure the following requirements are met before startup:
•
The drive unit is undamaged and not blocked.
•
The measures stipulated in chapter "Extended storage of motors" are performed
after extended storage periods.
•
All connections are installed correctly.
•
The direction of rotation on the drive unit matches the application.
•
All protective covers are installed correctly.
•
All motor protection equipment is active and set for the rated motor current.
•
In general, there must be no other sources of danger present.
•
The surface of the drive unit must not be covered by heat-sensitive or insulating
materials.
6.2.2
During startup
Make sure that the motor is running correctly during startup. During startup, none of
the following problems must occur:
•
Overload
•
Speed fluctuations
•
Loud noises
•
Noticeable vibrations etc.
In case of problems, refer to chapter "Service".
25805134/EN – 07/2018