12
Compact Operating Instructions – MOVIMOT® MM..D with DRS/DRE/DRP AC Motor
4
MOVIMOT
®
gearmotor installation
Mechanical Installation
4
Mechanical Installation
4.1
MOVIMOT
®
gearmotor installation
4.1.1
General information
• Observe the general safety notes.
• Strictly observe all instructions as to the technical data and the permissible condi-
tions regarding the place of installation.
• Only use the provided attachment options when mounting the MOVIMOT
®
drive.
• Only use mounting and locking elements that fit into the existing bores, threads and
countersinks.
4.1.2
Installation requirements
Make sure that the following requirements are met before you start installing the unit:
• The data on the nameplate of the drive matches the voltage supply system.
• The drive is undamaged (no damage caused by transportation or storage)
• Ambient temperature corresponds to the specifications in chapter "Technical Data"
of the MOVIMOT
®
operating instructions. Note that the temperature range of the
gear unit may also be restricted (see gear unit operating instructions).
• The MOVIMOT
®
drive must not be installed under the following harmful ambient con-
ditions:
– Potentially explosive atmospheres
– Oils
– Acids
– Gases
– Vapors
– Radiation
– etc.
• When the drive is installed in abrasive ambient conditions, protect the output end oil
seals against wear.
Installation toler-
ances
The following tables shows the permitted tolerances of the shaft ends and flanges of the
MOVIMOT
®
drive.
Shaft end
Flanges
Diameter tolerance according to EN 50347
•
ISO j6 with Ø
≤
26 mm
•
ISO k6 with Ø
≤
38 mm up to
≤
48 mm
•
ISO m6 at Ø > 55 mm
•
Center bore in accordance with DIN 332,
shape DR..
Centering shoulder tolerance in accordance
with EN 50347
•
ISO j6 with Ø
≤
250 mm
•
ISO h6 with Ø > 300 mm