Compact Operating Instructions – MOVIMOT® MM..D with DRS/DRE/DRP AC Motor
23
5
Connection between MOVIMOT
®
and motor when mounted close to the
Electrical Installation
5.3
Connection between MOVIMOT
®
and motor when mounted close to the motor
If the MOVIMOT
®
inverter is mounted close to the motor, the connection to the motor is
realized with a pre-fabricated hybrid cable.
Use only hybrid cables from SEW-EURODRIVE to connect the MOVIMOT
®
inverter with
the motor.
The following designs are possible on the MOVIMOT
®
side:
• A: MM../P2.A/RO.A/
APG4
• B: MM../P2.A/RE.A/
ALA4
The APG4 type results in the following connection options to the motor, depending on
the hybrid cable used:
Design
A1
A2
A3
A4
MOVIMOT
®
APG4
APG4
APG4
APG4
Motor
Cable gland/
terminals
ASB4
APG4
ISU4
Hybrid cable
0 186 742 3 0 593 076 6 0 186 741 5 0 816 325 1
for DR.63
0 816 326 X
for DR.71–DR.132
0 593 278 5
for DR.63
0 593 755 8
for DR.71–DR.132
[1] Connection via terminals
458666635
A2
A3
ASB4
APG4
APG4
APG4
APG4
ISU4
A4
A1
APG4
[1]