Compact Operating Instructions – MOVIMOT® MM..D with DRS/DRE/DRP AC Motor
6
Startup with binary control
"Easy" Startup
6.5
Startup with binary control
1. Check whether the MOVIMOT
®
drive is installed correctly both mechanically and
electrically.
See chapters "Mechanical Installation" and "Electrical Installation".
2. Make sure that the DIP switches S1/1 – S1/4 are set to "OFF" (address = 0).
This means MOVIMOT
®
is controlled binary via terminals.
3. Set the first speed at the setpoint potentiometer f1 (active when terminals f1/f2 X6:7,8
= "0"), factory setting: about 50 Hz (1500 rpm).
4. Make sure the screw plug of the setpoint potentiometer f1 has a seal and screw it in.
NOTICE
Loss of warranted degree of protection if the screw plugs of the f1 setpoint
potentiometer or the X50 diagnostics interface are installed incorrectly or not at all.
Damage to the MOVIMOT
®
inverter.
• Make sure the screw plug of the setpoint potentiometer has a seal and screw it in.
WARNING
Electric shock caused by dangerous voltages in the connection box. Dangerous volt-
ages may still be present for up to one minute after disconnection from the power sup-
ply.
Severe or fatal injuries.
• De-energize the MOVIMOT
®
drive using a suitable cut-off device before removing
the MOVIMOT
®
inverter.
• Secure the inverter against unintended re-connection to the voltage supply.
• Wait for at least 1 minute before removing the inverter.