6
Startup of MOVIMOT
®
with MLK30A in Easy mode
General information concerning startup
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
35
6
Startup of MOVIMOT
®
with MLK30A in Easy mode
6.1
General information concerning startup
INFORMATION
You must comply with the general safety notes in the chapter "Safety notes" during
startup.
WARNING
Risk of crushing due to missing or defective protective covers.
Severe or fatal injuries.
• Install the protective covers of the plant according to the instructions, also see
the operating instructions of the gear unit.
• Never start the unit if the protective covers are not installed.
WARNING
Electric shock from capacitors that have not been fully discharged.
Severe or fatal injuries.
• Disconnect the inverter from the power. Observe the minimum switch-off time af-
ter disconnection from the supply system:
–
1 minute
WARNING
Device malfunction due to incorrect device setting.
Severe or fatal injuries.
• Comply with the startup instructions.
• The installation must be carried out by qualified personnel only.
• Always use the appropriate functional settings.
WARNING
Danger of burns due to hot surfaces of the unit (e.g. the heat sink).
Serious injuries.
• Do not touch the unit until it has cooled down sufficiently.
INFORMATION
To ensure fault-free operation, do not disconnect or connect power or signal lines
during operation.
INFORMATION
• Remove the paint protection caps from the status LED and the two AS-Interface
LEDs before startup. Remove paint protection film from the nameplates before
startup.
• Observe a minimum switch-off time of 2 seconds for the K11 line contactor.
21328994/EN – 11/2014