2
Safety notes
Installation
Compact Operating Instructions – MOVIMOT
®
MM..D with AS-Interface
9
2.6
Installation
The units must be installed and cooled according to the regulations and specifications
contained in the corresponding documentation.
Protect the MOVIMOT
®
inverters from excessive strain.
The following applications are prohibited unless explicitly permitted:
• Use in potentially explosive areas.
• Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc.
• Use in non-stationary applications with strong mechanical oscillation and impact
loads; see operating instructions, chapter "Technical data".
2.7
Electrical connection
Observe the applicable national accident prevention regulations when working on live
MOVIMOT
®
inverters (e.g. BGV A3).
Perform electrical installation according to the relevant regulations (e.g. cable cross
sections, fusing, PE connection). For any additional information, refer to the applicable
documentation.
For notes on EMC compliant installation, such as shielding, grounding, arrangement of
filters and routing of lines, refer to chapter "Installation instructions". The manufacturer
of the system or machine is responsible for maintaining the limit values established by
EMC legislation.
Preventive measures and protection devices must comply with the regulations in force
(e.g. EN 60204-1 or EN 61800-5-1).
To ensure insulation, you must perform voltage checks on MOVIMOT
®
drives before
startup, in accordance with EN 61800-5-1:2007, chapter 5.2.3.2.
2.8
Protective separation
MOVIMOT
®
inverters meet all requirements for protective separation of power and
electronic connections in accordance with EN 61800-5-1. All connected circuits must
also satisfy the requirements for protective separation to ensure reliable separation.
21328994/EN – 11/2014