114
Manual – MOVIPRO® SDC with DeviceNet Interface
10
Explanation of the parameters
Parameterization of MOVIPRO
®
The "Speed skip" function makes it possible to prevent the motor speed from remaining
within a certain speed window. This suppresses vibration and noise, in particular in ma-
chines with pronounced mechanical resonance.
P740/P742 Skip
window center 1/2
Setting range: 0 – 1500 – 600 rpm
P741/P743 skip
width 1/2
Setting range: 0 – 300 rpm
1
2
1
2
0
0
I