Manual – MOVIPRO® SDC with DeviceNet Interface
129
10
Explanation of the parameters
Parameterization of MOVIPRO
®
P94x IPOS encoder
P941 Source of
actual position
Setting range: Motor encoder / Ext. Encoder
Defines the encoder to which the application module positions.
P948 Automatic
encoder replace-
ment detection
Setting range: On/off
This parameter is only effective with HIPERFACE
®
encoders.
• On: A replaced HIPERFACE
®
encoder is detected. Reference travel is required be-
fore the "IPOS referenced" bit is set.
• Off: The HIPERFACE
®
encoder is always referenced. The "IPOS referenced" bit is
set.
NOTE:
If P948 is switched off and on again, the "IPOS referenced" bit is set to "0"
once you have restarted the MOVIPRO
®
. Reference travel is necessary to rest the
"IPOS referenced" bit to "1".
P96x IPOS modulo
function
The IPOS
plus®
modulo function is used for endless positioning, for example with circular
indexing tables or chain conveyors.
P960 Modulo func-
tion
Setting range: Off / Short / CW / CCW
• Off: The modulo function is deactivated.
• In short: The "short travel" modulo function is active. The drive moves from the actual
position to the target position taking the shortest possible route. Both directions of
rotation are possible.
• CW: The "CW" modulo function is active. The drives moves from its actual position
to the target position with a "CW" direction of rotation, even if this means moving a
longer distance. The "CCW" direction of rotation is not possible.
• CCW: The "CCW" modulo function is active. The drives moves from its actual
position to the target position with a "CCW" direction of rotation, even if this means
moving a longer distance. The "CW" direction of rotation is not possible.
P961 Modulo
numerator
Setting range: 1 – (2
31
−
1)
Simulation of the gear unit by entering the number of teeth of the gear unit and the ad-
ditional gear.
Modulo numerator = Numerator gear unit i × numerator additional gear i
P962 Modulo
denominator
Setting range: 1 – (2
31
−
1)
Simulation of the gear unit by entering the number of teeth of the gear unit and the ad-
ditional gear.
Modulo denominator = Denominator gear unit i × denominator additional gear i
P963 Modulo
encoder resolution
Setting range: 1 – 4096 – 65535
Resolution of the selected IPOS
plus®
encoder system in increments.
The IPOS
plus®
encoder resolution for positioning to the motor encoder is set to 4096 in-
crements (prerequisite is an encoder resolution of 512 to 2048).
0
0
I