134
Manual – MOVIPRO® SDC with DeviceNet Interface
11
MOVIPRO
®
SDC error list
Service
10
IPOS-ILLOP
Emergency
stop
0
Invalid IPOS
plus®
command
•
Incorrect command
detected during
execution of the
IPOS
plus®
program
•
Incorrect conditions
during command
execution
•
Check the content of the
program memory and, if
necessary, correct.
•
Load the correct program
into the program memory
•
Reload the application
module
11
Overtempera-
ture
Emergency
stop (P)
0
Heat sink temperature too high
or defective temperature sen-
sor
Thermal overload of
inverter
Reduce load and/or ensure
adequate cooling
3
Overtemperature switched-
mode power supply
14
Encoder
Immediate dis-
connection
0
Encoder not connected, defec-
tive encoder, defective
encoder cable
•
Encoder cable or
shield not
connected correctly
•
Short circuit/broken
encoder wire
•
Encoder defective
Check encoder cable and
shield for correct connection,
short circuit and broken wire.
25
Motor encoder error – Speed
range exceeded
Encoder exceeds 6542 rpm
26
Motor encoder error – Card is
defective.
Error in the quadrant evalua-
tion.
27
Encoder error – encoder con-
nection or encoder is defective
28
Encoder error – Communica-
tion error RS485 channel.
29
External encoder error – Com-
munication error RS485 chan-
nel
30
Unknown encoder type on the
external encoder/motor
encoder
31
Plausibility error of
HIPERFACE
®
on the external
encoder/motor encoder
Increments have been lost.
32
HIPERFACE
®
motor encoder
error
HIPERFACE
®
encoder on
motor encoder reports an error
33
HIPERFACE
®
external
encoder error
HIPERFACE
®
encoder on
external encoder reports an
error
34
Revolver motor encoder error
Encoder connection or
encoder is defective.
17
System mal-
function
Immediate dis-
connection
0
"Stack overflow" error
Inverter electronics dis-
rupted, possibly due to
effect of EMC
•
Check grounding and
shielding and improve, if
necessary
•
Consult SEW service if the
error occurs again
18
0
"Stack underflow" error
19
0
Fault "External NMI"
20
0
Fault "Undefined opcode"
21
0
"Protection fault" error
22
0
"Illegal word operand access"
error
23
0
"Illegal instruction access"
error
24
0
"Illegal external bus access"
error
Error
Suberror
Code Designation
Response (P) Code Designation
Possible cause
Measure