Manual – MOVIPRO® SDC with DeviceNet Interface
137
11
MOVIPRO
®
SDC error list
Service
59
Encoder com-
munication
Rapid stop
1
HIPERFACE
®
encoder: Track
signal error
2
HIPERFACE
®
encoder: Cali-
bration error
Incorrect calibration of
encoder
•
Restore factory settings
(P802)
•
Repeat encoder startup
16
HIPERFACE
®
encoder: Com-
munication error
MOVIPRO
®
and
HIPERFACE
®
encoder
connection interrupted
Check wiring
64
128
192
256
320
384
448
512
576
1024
EnDat encoder: Communica-
tion error
MOVIPRO
®
and EnDat
encoder connection
interrupted
Check wiring
1088
1152
1216
1280
1388
16385
HIPERFACE
®
synchronous
encoder: Track signal error
16386
HIPERFACE
®
synchronous
encoder:
Incorrect calibration of
encoder
•
Restore factory settings
(P802)
•
Repeat encoder startup
59
Encoder com-
munication
Rapid stop
16400 HIPERFACE
®
synchronous
encoder: Communication error
MOVIPRO
®
and
HIPERFACE
®
synchro-
nous encoder connec-
tion interrupted
Check wiring
16448
16512
16576
16640
16704
16768
16832
17408 EnDat synchronous encoder:
Communication error
MOVIPRO
®
and EnDat
synchronous encoder
connection interrupted
Check wiring
17472
17536
17600
17664
17772
77
IPOS control
word
No response
(P)
0
Invalid control word IPOS
plus®
Only in IPOS
plus
®
mode:
•
An attempt was
made to set an
invalid automatic
mode (via external
controller).
•
"P916 = Bus ramp"
is set.
•
Check serial connection to
external controller
•
Check write values of
external controller
•
Set correct value for P916
78
IPOS SW limit
switch
No response
(P)
0
Software limit switch reached
Only in IPOS
plus
®
mode:
Programmed target
position is outside travel
range delimited by soft-
ware limit switches.
•
Check the user program
•
Check position of software
limit switches
80
RAM test
Immediate dis-
connection
0
"RAM test" error
Internal unit fault, RAM
defective.
Consult SEW Service
Error
Suberror
Code Designation
Response (P) Code Designation
Possible cause
Measure