Manual – MOVIPRO® SDC with DeviceNet Interface
5
Configuring the PLC and master (DeviceNet scanner)
Configuration and Startup on the DeviceNet Fieldbus
5.2
Configuring the PLC and master (DeviceNet scanner)
The following samples refer to the usage of an Allen-Bradley-PLC ControlLogix 1756-
L61 together with the RSLogix 5000 programming software and the DeviceNet configu-
ration software RSNetWorx for DeviceNet.
After adding the DeviceNet scanner to the I/O configuration, the DNT file containing the
DeviceNet configuration is selected. To view and edit the DeviceNet configuration,
RSNetWorx can be launched from this dialog:
In RSNetWorx for DeviceNet (see following figure), either perform an online scan or add
the required devices to the graph by drag and drop. The address given under the icon
of the device must be equal to the MAC-ID set by the DIP switches of the MOVIPRO
®
.
If the selection list does not include the required devices, corresponding EDS files have
to be registered via [Tools] / [Wizard].