Manual – MOVIPRO® SDC with DeviceNet Interface
29
5
Configuration examples in RSLogix 5000
Configuration and Startup on the DeviceNet Fieldbus
5.3
Configuration examples in RSLogix 5000
5.3.1
MOVIPRO
®
with 8 process data words
1. Set the respective DIP switches on the MOVIPRO
®
to
• adjust the baud rate to the DeviceNet
• set the address (MAC-ID) to a value used by no other node
2. Add the MOVIPRO
®
to the DeviceNet configuration as shown in chapter "Configuring
the PLC and master (DeviceNet scanner)" (page 26).
3. Set the number of process data words of MOVIPRO
®
to 8.
4. You can now start integration into the RSLogix project.
Generate a controller tag with a user-defined data type [1] to get a plain interface to
the inverter’s process data.
The description for the process input and output data of the controller tag can match
the definition of the process data (PD) in MOVIPRO
®
.
5. In order to copy the data from MOVIPRO
®
to the new data structure, a CPS com-
mand is added into the "MainRoutine" that reads the data from the local I/O:
1967466379
[1]