Manual – MOVIPRO® SDC with DeviceNet Interface
57
8
Process data of power section
Process Data Description
The following figure shows the prioritization for the evaluation of bits relevant for enable
in control word 1:
7
Reserved
For reserved bits, the value 0 must be transferred
for later use
8
Direction of rotation for motor potenti-
ometer
0 = CW direction of rotation
1 = CCW direction of rotation
9 – 10
Motor potentiometer acceleration/
deceleration
10 9
0
0
= No change
1
0
= Down
0
1
= Up
1
1
= No change
11 – 12
Selection of the internal fixed set-
points n11 – n13 and n21 – n23
12 11
0
0
= Speed setpoint via PO2
0
1
= Internal setpoint n11 (n21)
1
0
= Internal setpoint n12 (n22)
1
1
= Internal setpoint n13 (n23)
13
Changing the fixed setpoint
0 = Fixed setpoints of the active parameter set
selectable via bit 11/12
1 = Fixed setpoints of the other parameter set
selectable via bit 11/12
14 – 15
Reserved
For reserved bits, the value 0 must be transferred
for later use
9007200623660683
Bit
Meaning
Explanation
Controller inhibit
Immediate stop
Stop
Processing
enable
Hold control
Enable
0
0
I