Overview of parameters
Parameterization of MOVIPRO
®
505
Synchronous encoder monitoring
Off
52x
Mains OFF monitoring
520
Mains OFF response time
0 – 5 s
521
Mains OFF response
On
522
Phase failure monitoring
On
53x
Motor temperature protection
530
Sensor type 1
No sensor
531
Sensor type 2
No sensor
54x
Gear unit/motor monitoring
540
Response to vibration/warning
Display error
541
Response to vibration/error
Rapid stop/warning
542
Response to oil aging/warning
Display error
543
Response to oil aging/fault
Display error
544
Response to oil aging/overtemperature
Display error
545
Response to oil aging/ready
Display error
549
Response to brake wear
Display error
56x
Current limitation Ex-e motor
560
Current limit Ex-e motor
Off
561
Frequency A
0 – 5 – 60
562
Current limit A
0 – 50 – 150 %
563
Frequency B
0 – 10 – 104 Hz
564
Current limit B
0 – 80 – 200 %
565
Frequency C
0 – 25 – 104 Hz
566
Current limit C
0 – 100 – 200 %
6xx
Terminal assignment
60x
Binary inputs of basic unit
601
Binary input DIØ2
No function
602
Binary input DIØ3
No function
603
Binary input DIØ4
No function
604
Binary input DIØ5
No function
7xx
Control functions
70x
Operating modes
700 / 701
Operating mode 1 / 2
VFC
702
Motor category
Rotatory
71x
Standstill current
710 / 711
Standstill current 1 / 2
0 – 50 % I
Mot
72x
Setpoint stop function
720 / 723
Setpoint stop function 1 / 2
Off
721 / 724
Stop setpoint 1 / 2
0 – 30 – 500 rpm
722 / 725
Start offset 1 / 2
0 – 30 – 500 rpm
73x
Brake function
730 / 733
Brake function 1 / 2
On
731 / 734
Brake release time 1 / 2
0 – 2 s
732 / 735
Brake application time 1 / 2
0 – 2 s
74x
Speed skip function
740 / 742
Skip window center 1 / 2
0 – 1500 – 6000 rpm
741 / 743
Skip width 1/2
0 – 300 rpm
Parameter
Name
Value
0
0
I