112
Manual – MOVIPRO® SDC with DeviceNet Interface
10
Explanation of the parameters
Parameterization of MOVIPRO
®
functions, such as premagnetization, brake control, etc. It always requires an additional
enable via terminals.
P720/P723 Set-
point stop function
1/2
Setting range: On/off
P721/P724 Stop
setpoint 1/2
Setting range: 0 – 30 – 500 rpm
In the "VFC & Hoist" operating mode, the minimum stop setpoint is internally limited to
16 rpm.
P722/P725 Start
offset 1/2
Setting range: 0 – 30 – 500 rpm
There is no enable for stop se start offset (start setpoint) > n
max
.
Movement with n
min
is never possible if the stop setpoint is > n
min
.
P73x Brake func-
tion
The power section is capable of controlling a brake installed on the motor. The brake
function acts on the binary output DBØØ, which has the fixed assignment of the “/Brake”
function (24 V = brake released). In drives with encoder feedback (speed control), it is
possible to select between electrical holding of the load and mechanical application of
the brake in halt condition.
9007199533486731
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
120
60
120
60
30
0
0
t11
t11
t13
Stop
setpoint
n
set
n
actual
/controller
inhibit
CW/stop
Enable/
stop
/Brake
Integrator
input
Integrator
output
t11 up CW
t11 down CW
Stop
ramp t 13
Premagnetization
time
Premagnetization
time
Brake
release time
Brake
release time
Brake appli-
cation time
Brake appli-
cation time
Start
offset
t
t
t
t
t
t
min
-1
min
-1
1
2
1
2
1
2
INFORMATION
The brake is always applied when "/Controller inhibit" = 0.
0
0
I