Manual – MOVIPRO® SDC with DeviceNet Interface
113
10
Explanation of the parameters
Parameterization of MOVIPRO
®
P730/P733 Brake
function 1/2
Setting range: On/off
This function determines whether the brake is to be activated when the enable is with-
drawn (enable = "0"). The brake is always active in controlled hoist operation.
P731/P734 Brake
release time 1/2
Setting range: 0 – 2 s
The brake release time of the matching motor is set as the factory setting.
This parameter determines how long the motor will remain at a standstill after expiration
of the premagnetizing time and how much time the brake has to release.
P732/P735 Brake
application time 1/
2
Setting range: 0 – 2 s
The brake application time of the matching motor is set as the factory setting.
Serves to set the time required for application of the mechanical brake. This parameter
prevents a sagging of the drive (particularly in hoists).
P74x Speed skip
The skip window center and skip width are values and automatically have an effect on
positive and negative setpoints when activated. The function is deactivated by setting
the skip width to 0.
278749067
t
0
t
t
t
t
t
t
"1"
"1"
"1"
"1"
"0"
"0"
"0"
"0"
Rotary field in
Brake
release time
Brake appl.
time
Output stage in
Premagnetization time
/BRAKE
Enable
nset
nstart-stop
n
Post-magentization time
1
2
1
2
AUTO
1
2
AUTO
278752395
P741/P743
P740/P742
n setpoint
(integrator
input)
Ramps
t11/t12
n setpoint
n setpoint
(integrator
output)
Output speed
n setpoint
positive and negative
0
0
I