3
Safety concept
Drive safety functions according to EN 61800-5-2
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
21
3.7.4
SS1(a) – Safe Stop 1 with control and monitoring of the deceleration ramp
When the SS1(a) function is active, the drive inverter brings the motor to a standstill e-
lectrically. The deceleration behavior is not controlled and monitored in a safety-re-
lated manner. The STO drive safety function is triggered when the monitored deceler-
ation is exceeded or when standstill is reached.
This drive safety function corresponds to a controlled stop of the drive according to
EN 60204-1, stop category 1.
t
1
t
2
t
V
28259416075
= Drive safety function controls and monitors
= STO drive safety function active
v
= Speed
t
= Time
t
1
= Point in time when SS1(a) is activated and motor deceleration is triggered.
t
2
= Point of time when STO is triggered.
28482271/EN – 03/2019