10
Data exchange with higher-level controller
F process data profile
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
103
Byte Bit
Name
Value Description
1
0
Reserve
1
Reserve
2
Reserve
3
Reserve
4
Reserve
5
Reserve
6
Reserve
7
Reserve
2
0
Reserve
1
Reserve
2
SSX1
0
Activate SSx1.
1
Deactivate SSx1.
3
SSX2
0
Activate SSx2.
1
Deactivate SSx2.
4
Reserve
5
Reserve
6
Reserve
7
Reserve
Process input data
Byte Bit
Name
Value Description
0
0
STO1
0
STO is not active. Safe disconnection of the drive is
not active.
1
STO signals the status "STO active". All outputs
parameterized to STO are switched off.
1
Reserve
2
Reserve
3
Input data
valid
0
At least one of the F-DI process values sends a sub-
stitute value.
1
All process values of the F-DI contain actual values.
4
Reserve
5
Reserve
6
Warning
0
The safety card is in error-free operation.
1
At least one warning in the safety card is active.
7
Fault
status
0
The safety card is in error-free operation.
1
At least one fault in the safety card.
28482271/EN – 03/2019