12
Service
"Emergency mode" function
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
121
12.5.1
Safety notes
DANGER
Due to the "Emergency mode" function, immediate restart of the system is possible.
Severe or fatal injuries.
•
Before activation of the "Emergency mode" function, the user must undertake or-
ganizational measures for the protection of personnel and machinery.
DANGER
The keypad is connected to the wrong device. This can cause immediate restart of
the system.
Severe or fatal injuries.
•
Before activation of the "Emergency mode" function, the user must undertake or-
ganizational measures for the protection of personnel and machinery.
•
The keypad must mechanically be connected to the correct device.
•
Make sure that you can see the display of the keypad at any time during emer-
gency mode.
12.5.2
Approved devices
The "Emergency mode" function is approved for MOVIDRIVE
®
technology with
MOVISAFE
®
CS..A safety card.
12.5.3
Requirements
•
The "Emergency mode" function (index 8702.2) must be enabled.
•
To start the "emergency mode" function, an encoder fault or communication error
must be pending in the F-protocol.
12.5.4
Starting emergency mode
Proceed as follows:
•
Select "emergency mode" using the keypad.
•
With the "F-ERR" LED (see chapter "F-ERR LED"), check if the correct device sig-
nals emergency mode. If the wrong device is flashing, activation of the emergency
mode must be canceled immediately.
•
If the correct device is selected, the emergency mode ID is displayed. Confirm sig-
naling of the correct device. For this, enter the displayed emergency mode ID in
reverse order and click OK.
12.5.5
Ending emergency mode
•
You can end emergency mode in a safety-related manner by interrupting the con-
nection between keypad and device.
•
You cannot end emergency mode in a safety-related manner by selecting "End
emergency mode" on the keypad.
28482271/EN – 03/2019