12
Service
Device replacement
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
125
12.7.1
Device replacement with MOVI-C
®
CONTROLLER
The following steps must be performed for the actual device replacement:
The system offers the option to save the application-related data set for the inverter
and the data set for the safety card on the controller. This step must be carried out in
advance by the user.
1. Switch off the device to be replaced.
2. Pull the pluggable safety key from the safety card.
3. Replace the device (including MOVISAFE
®
CS..A safety card) or only the
MOVISAFE
®
CS..A safety card.
4. Re-insert the safety key pulled out in step 2.
5. Carry out a functional test. The checking of all parameters is omitted.
The controller detects the device replacement automatically and loads the application-
related data set to the MOVISAFE
®
CS..A safety card. The localized key data set on
the safety key ensures that the correct application-related data set has been loaded.
The MOVISAFE
®
CS..A safety card is subsequently in the same state that it was in
before the device replacement. This means that the MOVISAFE
®
CS..A safety card
will be in the "Accepted" state again afterwards if it was in the "Accepted" state before
the device replacement. In order to ensure correct connection of the sensors and actu-
ators, a function test of the safety card is still required in the case of automatic device
replacement function.
12.7.2
Device replacement with MOVISUITE
®
For device replacement with MOVISUITE
®
, proceed as follows:
1. Back up the device data set of the device to be replaced with the menu item
[Device] > [PC].
2. Switch off the device to be replaced.
3. Pull the pluggable safety key from the safety card.
4. Replace the device (including MOVISAFE
®
CS..A safety card) or only the
MOVISAFE
®
CS..A safety card.
5. Re-insert the safety key pulled out in step 3.
6. Switch only the DC 24 V control voltage back on.
7. Load the device data set saved in step 1 back onto the new device with the menu
item [PC] > [Device].
8. Switch the main power supply (AC 230 V) back on and perform a functional test of
the system.
28482271/EN – 03/2019