13
Technical data
Characteristic safety values
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
129
F-DO00_P/M, F-DO01_P/M
Value/description
Load inductance with freewheeling
diode
≤ 40 H
Minimum load resistance
> 130 Ω
13.7
Characteristic safety values
13.7.1
Drive safety functions without encoder evaluation
Characteristic values pursuant to
EN 62061/IEC 61800-5-2 EN ISO 13849-1
Tested safety class/underlying
standards
SIL 3
PL e
Probability of dangerous failure per
hour (PFH
D
value)
4.5 × 10
-9
1/h
Mission Time/service life
20 years, after which the component must be
replaced with a new one.
Proof test interval
20 years
-
Safe state
Value "0" for all safe F-DO process values (out-
put disabled).
Drive safety function
•
STO, SS1(c), SBC
•
Safe digital inputs/outputs
•
Safe communication
INFORMATION
In the case of 1-pole wiring of the safe digital inputs/outputs, the feasible safety inte-
grity level pursuant to EN 62061/IEC 61800-5-2 is reduced to SIL 2 or the perform-
ance level pursuant to EN ISO 13849-1 is reduced to PL d. Continue to observe the
installation requirements.
13.7.2
Drive safety functions with encoder evaluation
Characteristic values pursuant to
EN 62061/IEC 61800-5-2 EN ISO 13849-1
Tested safety class/underlying
standards
SIL 2
PL d
Probability of dangerous failure per
hour (PFH
D
value)
4.5 × 10
-9
1/h
Mission Time/service life
20 years, after which the component must be re-
placed with a new one.
Proof test interval
20 years
-
Safe state
Value "0" for all safe F-DO process values (out-
put disabled).
Drive safety function
SS1, SS2, SOS, SLS, SSM, SSR, SDI, SLI, SLA
28482271/EN – 03/2019