5
Device structure
Compatibility
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
40
Device status MOVIDRIVE
®
system CiA402 (MDX9.A.-E00)
Size
Device status location
Firmware version of the CS..A
safety card
1
2
3
4
5
6
7
8
9 1.05
2.05
1 – 5
xx xx 15 00 xx xx xx xx xx - Not permitted.
OK
The "xx" entries have no effect on compatibility.
For a CS..A safety card with firmware version 2.05, MOVIDRIVE
®
firmware version
4.00 or higher is required.
5.5.2
CS..A safety card firmware version and MOVISUITE
®
version
Use of the CS..A safety card depends on:
•
The firmware version of the CS..A safety card.
•
The version of the MOVISUITE
®
engineering software.
Firmware version 2.05 and later
CS..A safety cards with firmware version 2.05 and higher can only be used with
MOVISUITE
®
engineering software version 2.1 and higher. The following table shows
the available CS..A safety cards with the corresponding part numbers.
CS..A safety card
Firmware version
CS..A part number
CSB21A
2.05 and higher
28233360
CSS21A
28233379
CSB31A
28233367
CSS31A
28233395
Firmware version 1.05
CS..A safety cards with firmware version 1.05 can only be used with MOVISUITE
®
en-
gineering software version 1.2 and 2.0.
When replacing cards during servicing, CS..A safety cards with firmware version 1.05
can be ordered as a service kit so that acceptance testing of the drive safety functions
is not required due to the change in firmware. The following table shows the available
safety kits with their corresponding part numbers.
Service kit
part number
Service kit (= CS..A safety card with
firmware version 1.05)
Valid for CS..A safety
card
28261976
Service kit CSB21A /FW1.05
CSB21A
28261984
Service kit CSS21A /FW1.05
CSS21A
28261992
Service kit CSB31A /FW1.05
CSB31A
28262018
Service kit CSS31A /FW1.05
CSS31A
28482271/EN – 03/2019