8
Startup
Safety-relevant acceptance
Manual – MOVISAFE
®
CS..A Safety Card (Version 2)
88
For unused drive safety functions, it is sufficient to verify whether the release is para-
meterized to "No".
8.8.1
Sequence
After a successful startup, you must confirm that the data of the acceptance report
matches the parameters on the safety card. You must identify and protocol the values
parameterized for the user units, sensors and monitoring functions individually by per-
forming a function test. All limit values of the safety card must be verified by exceeding
each limit value and then triggering the defined state (safe state = STO + brake de-en-
ergized). You must take this into account in the machine and system controls.
8.8.2
Creating an acceptance report
With the Assist CS.. tool integrated in MOVISUITE
®
, you can generate an individual
acceptance report and save it as a PDF. Before creating the report, enter the sys-
tem‑specific data in the Assist CS.. form. The system‑specific data is transferred to the
PDF file.
8.8.3
Structure of the acceptance report
The acceptance report that is generated as a PDF file contains the following informa-
tion:
•
System information
•
Parameters of the safety card
•
Overview of checksums
•
Communication data
28482271/EN – 03/2019