MC_SHELL

1

Introduction

1

Introduction

The MC_SHELL program makes it easy to set the parameters for and start up MOVITRAC

®

  31C fre-

quency inverters. The context-sensitive help menus provide assistance in all startup steps as well
as documentation for all settings which have been made.

Characteristics of the program    

• Startup, testing and diagnosis of all unit variants and associated options.
• Loading and saving parameter sets between the inverter and the PC.
• Creating or changing parameter sets on the PC without having the inverter connected.   
• Integrated function modules for

– manual control and setpoint entry via PC (“manual mode”),
– fieldbus diagnosis (“fieldbus monitor”),
– programming and diagnosis of the integrated IPOS positioning control.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Summary of Contents for MOVITRAC 31C

Page 1: ...08 198 96 T MOVITRAC 31C Frequency Inverters Manual MC_SHELL Edition 09 98 0921 1411 0998 UL C UL...

Page 2: ...the menu item Selecting parameters Move the cursor bar onto the parameter and press RETURN General window structure 01827AEN Supplementary documents 1 Window name 4 Button 2 Data which can be changed...

Page 3: ...Editing box 13 3 4 Interface 14 3 4 1 Interface PC interface 14 3 4 2 Interface Inverter address 14 3 5 Options 15 3 5 1 Options Language 15 3 5 2 Options Select colour set 15 3 5 3 Options Beep on 15...

Page 4: ...the program Startup testing and diagnosis of all unit variants and associated options Loading and saving parameter sets between the inverter and the PC Creating or changing parameter sets on the PC w...

Page 5: ...installation program Start the MC_SHELL program using the following command mc_shell exe The language selection window appears if MC_SHELL is started for the first time The various pro gram settings l...

Page 6: ...ng the RS 485 interface check the polarity of the two RS 485 cables Windows 95 Under Window 95 the operating system makes a fixed assignment of the serial interfaces for an application As a result it...

Page 7: ...s of the allocated frequency inverter appears in the status bar along the bottom of the screen Changing the address Select using Interface Inverter address 3 1 Environment The Environment menu contain...

Page 8: ...file To change the comment Press the key or click with the mouse Files List of all files in the current directory ending with par To select a file Move the cursor bar up and down then press the RETUR...

Page 9: ...enu commands 01985AEN Fig 6 Selection options in the Parameters menu 3 2 1 Parameters Commissioning 01986AEN Fig 7 Display the setting options in the Commissioning menu item The Commissioning window s...

Page 10: ...ding parameters Press the Ins key or click the INS button with the mouse Enter the required parameter num ber into the editing window Press the RETURN key The new parameter is added The following reas...

Page 11: ...he different units MC_SHELL automatically detects which type of unit has been connected 3 2 5 Parameters Unit status 02022AEN Fig 11 Current unit status The Unit status window is used for displaying t...

Page 12: ...gnostic tool for using the inverter in conjunction with a fieldbus The bus monitor window cannot be opened if MC_SHELL is in offline mode see Interface PC interface and the inverter is a type MC31C eq...

Page 13: ...can be selected by a programmable input terminal This means you can use two motors with one unit for different drive tasks 3 3 2 Lists Editing box 01997AEN Fig 15 Editing box for editing parameter fil...

Page 14: ...which the inverter is connected If the window fails to close after you have selected the interface and confirmed your selection this indi cates that the interface is not present or is occupied 3 4 2...

Page 15: ...in the MC_SHELL path 3 5 2 Options Select colour set 02003AEN Fig 20 The various colour sets in MC_SHELL It is possible to select one of 6 possible colour sets 3 5 3 Options Beep on Selecting this men...

Page 16: ...cture to the MC_SHELL CFG file 3 6 3 Screen Clear screen This function closes all windows on the user interface 3 6 4 Screen Autoconfiguration When the autoconfiguration is active the window structure...

Page 17: ...ew of the structure of the menu bar and the pos sibilities for selecting menu functions 3 8 2 Help Key assignment This function is used for explaining the functions of all keys and buttons in the wind...

Page 18: ...lled Selecting the Environment MC_SCOPE menu item causes the MC_SHELL program to be exited The MC_SCOPE program is started from the folder named Path MC_SHELL is exited in the normal way if Path and o...

Page 19: ...Selection 6 K Keyboard operation 2 M Menu functions 7 Menu overview 7 Mouse operation 2 MX_SHELL INI 18 MX_SCOPE Path 18 MX_USER MNU 18 MX_WIN DAT 18 O Overview of menus 7 P Parameters Adding 10 Delet...

Reviews: