5
Single-point synchronization
Restrictions of the parameters
Product Manual – MOVITRANS
®
TES31A Decentralized Supply Unit Synchronization
28
5.2
Restrictions of the parameters
Activating the synchronization function has the following effects:
•
That certain parameters can no longer be set to the full extent.
•
That the unit behavior changes in comparison to the unit behavior described in the
relevant MOVITRANS® TES31A Decentralized Supply Unit documentation.
Index
Parameter
Restrictions
Dec
Hex
Sub
8335
208E
0
Binary input DI01
Setting blocked.
8350
209E
0
Binary output DO01
Setting blocked.
8843
228B
0
Binary output DO00
Setting blocked.
8461
210D
0
Setpoint source
Master:
All sources except for
SBus2 can be set.
Slave:
Setting blocked.
8462
210E
0
Control signal source
Master:
All sources except for
SBus2 can be set.
Slave:
Setting blocked.
10235
27F9
1
"DC link under-
voltage" fault re-
sponse
Setting blocked.
10244
2804
1
"Sync timeout" fault
response
Setting blocked.
9729
2601
4
"Line phase failure"
fault response
Setting blocked.
10538
292A
100
Operating mode
Setting blocked.
10232
27F8
27
Ramp time T00
Master:
Do not set ramps to under
500 ms.
Slave:
Setting is ignored.
10232
27F8
28
Ramp time T01
Master:
Do not set ramps to under
500 ms.
Slave:
Setting is ignored.
10232
27F8
29
Ramp time T10
Master:
Do not set ramps to under
500 ms.
Slave:
Setting is ignored.
10232
27F8
30
Ramp time T11
Master:
Do not set ramps to under
500 ms.
Slave:
Setting is ignored.
29190657/EN – 04/2020