14
Manual – Data Matrix Positioning System PCV80A-F200-R4-V19-SEW
4
Installing the code strip
Installation
4.1.2
Code strips with different starting positions
Notes
•
Stop edges
Maintain a code pattern of 10 mm when attaching another code strip to the end of the
previous one.
•
Expansion joints
If the system covers long distances, expansion joints are integrated in the system
structure. We recommend to interrupt the code strip. The resulting gaps should be
20 mm wide (2 code grids).
•
Inclines and declines
If you mount the code strip in inclines [1] or declines [2], cut the code strip several
times at the transition point to the horizontal as shown below.
•
Code strips with different numbers of tracks
The PCV-AA20 code strip has two rows of codes to compensate for slight deviations
in the travel range in Y direction. The code strip is also available with other numbers
of rows. The order number for the code strip is PCV-AAx0. The letter "x" represents
the number of rows of code, which can be 1 or 2. More rows are available on request.
Contact us for more information.
Order designation
Description
PCV100M-AA20-0
Code strip 2-track, length: 100 m
Starting position: 0 m
PCV100M-AA20-10000
Code strip 2-track, length: 100 m
Starting position: 100 m
PCV100M-AA20-990000
Code strip 2-track, length: 100 m
Starting position: 9900 m
8069367307
Order designation
Description
PCV*M-AA10-*
Code strip, 1-track
PCV*M-AA20-*
Code strip, 2-track
PCV*M-AA40-*
Code strip, 4-track
...
...
[1]
[2]