18
Manual – Data Matrix Positioning System PCV80A-F200-R4-V19-SEW
4
Electrical connection
Installation
4.3
Electrical connection
The PCV80A read head is connected electrically using an 8-pin M12 x 1 connector on
the side of the housing. Power supply as well as communication with peripheral devices
is implemented using this connection. This connection also provides the configurable in-
puts and outputs of the read head.
For connecting the PCV80A read head to the PFF-HM31A safety controller, use the pre-
fabricated connection cables listed in chapter "Accessories". Connect the 8-pin M12 x 1
connector (see chapter "Wiring diagram for the 8-pin connector of PCV80A") to the side
of the housing of PCV80A, and the 4-pin M12 x 1 connector to terminal X4011 (see
chapter "X4011: RS485 interface – externally of PFF-HM31") of the safety controller.
4.3.1
Wiring diagram for the 8-pin connector of PCV80A
Connections 1 and 8 can be configured as inputs or outputs.
8069390987
8069394443
1
2
3
4
5
6
7
8
OUT 2 / IN 2
+ UB
Data +
Data -
OUT 1
IN 1
GND
OUT 3 / IN 3
1
4
6
7
8
5
3
2