3.FEATURES

l

Full Autorange for all functions.

l

Data Hold function freezes the reading.

l

Max Hold function holds the absolutely maximum
of readings.

l

Low battery indication.

l

Safety design throughout with no exposed metal
Parts, shielded banana plugs and recessed input 
terminals.

l

Ohm function ideal for checking continuity of
relays, transformers and motor coils.

l

Diode check function.

4.SPECIFICATIONS

Ranges

AC Voltage

400/600 V

AC Current

400/1000 A

DC Voltage

400/600 V

DC Current

400/1000 A

Resistance

400/2000 

Ù

Diode

400/2000 mV at 1mA

AC

DC

Resistance

±

(1.0%rdg+3dgt)

±

(1.5%rdg+3dgt)

*

Frequency Response 40Hz~500Hz

Range Resolution Accuracy
400 V 0.1 V
600 V 1 V
400 A

0.1 A

1000 A 1 A

Range Resolution Accuracy
400V

0.1V

600V

1V

400A

0.1A

1000A 1A

±

(0.75%rdg+3dgt)

±

(1.5%rdg+3dgt)

Range Resolution Accuracy
400

Ù

0.1

Ù

2000

Ù

1

Ù

*

Buzzer sounds below 38.0

Ù

±

(1.0%rdg+3dgt)

Summary of Contents for 3800 CL

Page 1: ...AC DC CLAMP METER INSTRUCTION MANUAL...

Page 2: ...signed and tested according to CE Safety Requirements for Electronic Measuring Apparatus EN 61010 1 EN 61010 2 32 and other safety standards Follow all warnings to ensure safe operation WARNING READ S...

Page 3: ...nductors or bus bars l Never clamp around any conductor carrying a voltage above 600V R M S l Rated environmental conditions 1 Indoor use 2 Installation Category III 3 Pollution degree II 4 Altitude u...

Page 4: ...x Hold function holds the absolutely maximum of readings l Low battery indication l Safety design throughout with no exposed metal Parts shielded banana plugs and recessed input terminals l Ohm functi...

Page 5: ...ode 400 2000 mV at 1mA AC DC Resistance 1 0 rdg 3dgt 1 5 rdg 3dgt Frequency Response 40Hz 500Hz Range Resolution Accuracy 400 V 0 1 V 600 V 1 V 400 A 0 1 A 1000 A 1 A Range Resolution Accuracy 400V 0...

Page 6: ...ication O L indicated Low Battery Indication sign appears on the display Response Time Approx 1 second Sample Rate Approx 2 times per second Temperature Humidity for Guaranteed 0 40 at 80 max relative...

Page 7: ...6 Dimensions 255 L x 80 W x 35 D mm Weight Approx 420g battery included Power Source 9V 6F22 x 1 Accessories Test leads Carrying case Instruction manual 9V 6F22 x 1...

Page 8: ...7 5 Instrument Layout 1000A CAT 600V MAX OFF AC V DC V AC A DC A W HOLD A ZERO W V CAT MAX 600V COM AC DC CLAMP METER z v w x y u...

Page 9: ...ands to conductor 3 Jaw Trigger Press to open the jaws 4 DCA zero adjust shaft 5 LCD Display 3 digit LCD with the maximum reading of 3999 6 Input Terminal 7 Rotary Switch 8 Max Button Hold the absolut...

Page 10: ...reading of display directly l If the reading exceed 600V maybe the reading value is wrong and it is dangerous refer to the safety notes 2 Current measurement l Switch to AC A range for AC current or D...

Page 11: ...measured l Insert the BLACK lead to the COM and the RED one to another l Connect the test leads to the circuit under test and read the display directly For diode test l Connect the test leads to the d...

Page 12: ...wer 2 Unscrew the battery cover and replace a new Battery Cleaning and Storage Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents If the meter is not to be use...