background image

DIGITAL  MILLIOHM METER

AND  RESISTANCE  TESTER

INSTRUCTION  MANUAL

4338 mO

Summary of Contents for 4338 mO

Page 1: ...DIGITAL MILLIOHM METER AND RESISTANCE TESTER INSTRUCTION MANUAL 4338 mO...

Page 2: ...INDEX 1 INTRODUCTION 2 SAFETY NOTES 3 FEATURES 4 SPECIFICATIONS 5 GENERAL 6 INSTRUMENT LAYOUT 7 MEASUREMENT 8 MAINTENANCE 9 FUSE REPLACEMENT PAGE 1 2 3 4 5 6 10 10 12 13 14...

Page 3: ...y standards Follow all warnings to ensure safe operation WARNING READ SAFETY NOTES NEXT PAGE BEFORE USING THE METER CAT IV Is for measurements performed at the source of the low voltage installation C...

Page 4: ...may be impaired Rated environmental conditions 1 Indoor Use 2 Installation Category IV 3 Pollution Degree 2 4 Altitude up to 2000 meters 5 Relative humidity 80 max 6 Ambient temperature 0 40 C Observe...

Page 5: ...k 110 00k 1 1000M 11 000M 110 0M auto ranging Maximum resolution of 0 1m Large LCD 68 34mm Relative mode Auto zero mode Data hold function MAX MIN function Power source 1 5V C battery 8 Long battery l...

Page 6: ...curacy 0 8 of reading 4 digits over the operating temperature range 0 C 40 C with the supplied test leads Resistance measurement Range Resolution Accuracy 110 00 0 01 0 2M 1 2 rdg 3dgt 2 40M 2 0 rdg 4...

Page 7: ...90 W 126 D mm Weight Approx 1848g battey included Power source 1 5V C battery 8 Low Battery Indication sign appears on the display when the battery voltage drops below accurate operating level Accesso...

Page 8: ...1 5 3 7 2 6 8 4 9 10 11 MAX MIN HOLD REL TEST TEST ON DIGITAL MILLIOHM METER AND RESISTANCE TESTER OFF 1100 0m 11000m m AUTO 110M 110 00 LOCK Test Leads Special Resistance Test Lead Specialized for 2...

Page 9: ...d 11000m 4 wire testing 3 P2 Termianl This is the P2 terminal which is used for m measurement for 1100 0m and 11000m 4 wire testing This terminal is also the COM terminal for resistance measurement fo...

Page 10: ...nce measurement for 110 00 110M 2 wire testing 6 Function Rotary Switch The function rotary switch is for selecting different functions 7 TEST Button The TEST Button is only available for m measuremen...

Page 11: ...OLD mode makes the meter stop updating the reading on the LCD Enabling HOLD function in automatic mode makes the meter switch to manual mode but the full scale range remains the same HOLD function can...

Page 12: ...C1 P1 P2 C2 four terminals for 4 wire m measurement Connect green red blue black test leads to C1 P1 P2 C2 4 terminals Connect the test leads to the object or device for measuring m as Fig 1 Turn the...

Page 13: ...fter testing RESISTANCE MEASUREMENT 2 wire method Use P2 C2 three terminals for 2 wire resistance measurement The first step is to connect the special resistance test lead to P2 and C2 terminals befor...

Page 14: ...g Turn the rotary switch to the position of 110 00 110M yellow area then get the resistance reading on the LCD It s not allowed to press the TEST button when the rotary switch is at the position of 11...

Page 15: ...tery cover and replace with new batteries 1 5V C battery 8 3 Re install the battery cover Cleaning and Storage WARNING To avoid electrical shock or damage to the meter do not get water inside the case...

Page 16: ...e meter case replace with a new fuse which has the same specification 200mA 250V 5 20mm Due to our policy of constant improvement and development we reserve the right to change specifications without...

Reviews: