9.

 

MAINTENANCE

 

AND

 

CLEANING

 

METHOD.

 

9.1

 

Battery

 

Replacement.

 

Your

 

insulation

 

tester's

 

battery

 

is

 

situated

 

under

 

the

 

tester.

 

The

 

display

 

will

 

indicate

 

when

 

battery

 

needs

 

to

 

be

 

replaced.

 

Disconnect

 

the

 

test

 

leads

 

from

 

the

 

instrument

 

and

 

removes

 

the

 

battery

 

cover

 

and

 

the

 

batteries.

 

Replace

 

with

 

eight

 

ALKALINE

 

1.5V

 

"C"size,

 

taking

 

care

 

to

 

observe

 

correct

 

polarity.

 

Replace

 

battery

 

cover.

 

9.2

 

Cleaning

 

&

 

Storage.

 

Periodically

 

wipe

 

the

 

case

 

with

 

a

 

damp

 

cloth

 

and

 

detergent.

 

Do

 

not

 

use

 

abrasives

 

or

 

solvents.

 

If

 

the

 

meter

 

is

 

not

 

to

 

be

 

used

 

for

 

long

 

periods

 

or

 

longer

 

than

 

60

 

days,

 

remove

 

the

 

batteries

 

and

 

store

 

them

 

separately.

 

 

Warning

 

To

 

avoid

 

electrical

 

shock

 

or

 

damage

 

to

 

the

 

meter,

 

do

 

not

 

get

 

water

 

inside

 

the

 

case.

 

 

Store

 

the

 

meter

 

in

 

a

 

dry

 

environment.

 

 

9.3

 

Calibration

 

&

 

Servicing

 

Both,

 

calibration

 

and

 

servicing

 

are

 

performed

 

only

 

at

 

an

 

approved

 

facility.

 

Contact

 

your

 

nearest

 

distributor

 

about

 

calibration

 

certificate

 

and

 

servicing

 

.

 

Before

 

returning

 

the

 

instrument,

 

ensure

 

that

 

:

 

the

 

leads

 

have

 

been

 

checked

 

for

 

continuity

 

and

 

signs

 

of

 

damage.

 

the

 

batteries

 

are

 

in

 

good

 

condition.

 

 
 
 
 
 
 
 
 
 

 

-19-

 

Summary of Contents for 6213A-IN

Page 1: ...itales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 6213A IN DIGITAL VAR...

Page 2: ...ingles www viaindustrial com TABLE OF CONTENTS Index 2 Front Panel Layout 3 Inside Lid Instructions 4 Safety precautions 5 8 Overview 9 Features 10 Connections 11 Specifications 12 Functions 13 15 Sp...

Page 3: ...AYSREADUSER SMANUALBEFOREOPERATINGTHISINSTRUMENT Useonlyonde energisedandisolated disconnectedsystem DONOTPROCEEDIFVOLTAGEPRESENT Checktestleadsfordefects Ifanycracksordamages replacewithnewtest leads...

Page 4: ...AR WARNING Thisinstrumentshould notbeusedinexplosive orinflammable environments although thereisunlikelytobea firehazardfromthe instrumentitself However arcingin faultyinsulation sparkingcausedwhen ma...

Page 5: ...or test leads Preparations for testing of power system grounding or close to it can leave personnel vulnerable to exposure caused by faults at or fed from the system under test transferred potentials...

Page 6: ...hey were new Always disconnect the test leads when changing the batteries by removing the cover which give access to the batteries Always double check the lead connections before making any measuremen...

Page 7: ...warning features should your Variable High Voltage Digital Insulation Meter be connected to a live system 1 3 Never open your Variable High Voltage Digital Insulation Meter except for battery replacem...

Page 8: ...gaOhmios 6213 IN SEW manual ingles www viaindustrial com 1 7 Your Variable High Voltage Digital Insulation Meter has a live circuit warning beeper If It is connected to a live circuit a rapid pulsatin...

Page 9: ...his bar graph is showing voltage output during the first 30 seconds of the test or during automatic discharge of circuits During the automatic discharge of the circuit tested the bar graph displays th...

Page 10: ...6 5KV 7KV 7 5KV 8KV 8 5KV 9KV 9 5KV 10KV Calculate Dielectric Absorption Ratio DAR Automatically Calculate Polarization Index PI Automatically Insulation resistance Auto Ranging on all ranges TM Bar g...

Page 11: ...Ohmios 6213 IN SEW manual ingles www viaindustrial com Medidores de aislamiento Megohmetros Digitales VDC GigaOhmios 6213 IN SEW manual ingles www viaindustrial com 4 CONNECTIONS INSULATOR HV 10kV VAR...

Page 12: ...5KV 5KV 10KV Measuring Range 800K 500G AUTO RANGING Accuracy 5 2 digits Power 8 x 1 5V Alkaline batteries Output Power Limit 1W Voltage Regulation Selected Voltage 20 5 of nominal value unless curren...

Page 13: ...test voltage press 10KV button 2 6 3 Insulation Resistance Measurement 5KVdc To Select 5KVdc test voltage press 5KV button 4 6 4 Insulation Resistance Measurement 2 5KVdc To Select 2 5KVdc test volta...

Page 14: ...certain time or to make comparison See Special Features for more Timer Functions 6 11 STOP test To stop the test in progress press the TEST button 3 The test will immediately stop discharge and the i...

Page 15: ...ed by a one second long beep accompanied by the HOLD message on the display DO NOT REMOVE LEADS UNTIL THE HOLD MESSAGE APPEARS ON THE DISPLAY 6 15 Replace Battery Warning Indicator If the battery ener...

Page 16: ...Polarization Index The Polarization Index or PI is the ratio of the Insulation Resistance measured at 10 Minutes divided per the Insulation Resistance measured at 1 Minute 10 Minutes after starting a...

Page 17: ...t any time before during and after the test It s your responsibility to ensure proper contact of the leads at all times Once a test is finished the testers will automatically discharge capacitive or i...

Page 18: ...6213 IN SEW manual ingles www viaindustrial com 8 PREPARATION FOR MEASUREMENT 8 1 Before testing always check the following At Power ON read the display to make sure the Replace Battery message is no...

Page 19: ...ng care to observe correct polarity Replace battery cover 9 2 Cleaning Storage Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents If the meter is not to be use...

Page 20: ...are not live before commencing testing Secure both test leads properly to the insulation to test and use guard lead to collect surface leakage Good contacts are necessary to avoid flashing at high vol...

Page 21: ...surface of the insulator is too high and therefore the insulator may require cleaning 4 Should your insulator require cleaning follow the procedures recommended by it s manufacturer 5 For Final Test a...

Page 22: ...r characteristics may deteriorate due to many factors Their material properties may deteriorate with time and frequency use as well as stress put on to them One of the factor we will be testing is the...

Page 23: ...ormers are painted or dipped with insulating varnish large power transformers are painted with High Voltage insulating paint of very high specifications Many Applications uses insulating material to p...

Page 24: ...arranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stability or reliability or which have...

Reviews: